Dual Automatic Switching Function Cyber Master CCU Air Conditioner Modular Design

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: M22

Payment & Shipping Terms

Minimum Order Quantity: 1Unit

Price: $1000.00-5000.00/set

Packaging Details: WOODED

Delivery Time: 20-40 days

Payment Terms: T/T, L/C

Supply Ability: 1000-5000/set/month

Get Best Price
Highlight:

Modular Design CCU Air Conditioning Systems

,

Automatic Switching CCU Air Conditioner

,

ISO9001 Approved CCU Air Conditioner

Color:
Black/Grey White/other Custom Colors
Mounting:
Floor Standing
Operating Voltage:
380/400 VAC,230 VAC,220V
Application:
Data Center, IT Room , Computer Room, Cold/hot Aisle
Power:
3N-380V-50Hz,220v/50hz/60hz
Product:
Precision Air Conditioning Unit/ Data Center Cooling Unit /computer Room Unit /close Control Unit
Color:
Black/Grey White/other Custom Colors
Mounting:
Floor Standing
Operating Voltage:
380/400 VAC,230 VAC,220V
Application:
Data Center, IT Room , Computer Room, Cold/hot Aisle
Power:
3N-380V-50Hz,220v/50hz/60hz
Product:
Precision Air Conditioning Unit/ Data Center Cooling Unit /computer Room Unit /close Control Unit
Dual Automatic Switching Function Cyber Master CCU Air Conditioner Modular Design

Dual Automatic Switching Function Cyber Master CCU Air Conditioner

 

 

Products Introduction                                                                         

                              

Cyber Master series constant temperature and humidity precision air conditioner is with modular design, high EER, large screen human-computer interface and intelligent control system. It has options of air-cooled, water-cooled, chilled water and double source cooled.

CyberMateTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMateTM meets the cooling demand and reduce the PUE of the data center.

 

 

 

 

Feature & Benefits                                                                                

                                   

Dual Automatic Switching Function Cyber Master CCU Air Conditioner Modular Design 0

Dual Automatic Switching Function Cyber Master CCU Air Conditioner Modular Design 1

 

Advantage                                                                                             

Dual Automatic Switching Function Cyber Master CCU Air Conditioner Modular Design 2
Designed to operate 24x7
Pathfinder is designed higher than the industry standards, suited for uninterrupted operation of all-weather under-40 ℃-+55 ℃ ambient conditions.
 
Intelligent control technology
Advanced intelligent control technology, Chinese/ English Large LCD backlit display, easy-to-human interface, precise microcomputer control system; can store 250 historical alarm information. With filter cleaning time alerts.
 
Phase sequence protection and Phase sequence fault tolerance
Phase sequence protective capability can realize the real-time detection of three-phase power. When the air conditioning fails to work in stable conditions due to phase absence,phase loss and phase sequence unbalance, the protector will make the air conditioning a mandatory stop to protect the unit itself.The sequence fault tolerance function allows self-identification and automatic conversion of phase sequence,ensuring the efficient and safe running of CRAC. No need for manual regulation.
 
Power failure memory and auto restarting
When power is re-supplied after a power failure, the air conditioning will continue to work in the previous mode set before the interruption of power.

 

Applications                                                                                                                               

„ Computer room and data center

„ Switch room and mobile center station in telecommunication

„ High-tech environment and lab

„ Industrial automation control room and precision manufacturing workshop

„ Standard test room and calibration center

„ UPS and battery room

„ Test room in hospital

„ Biochemical culture chamber

Dual Automatic Switching Function Cyber Master CCU Air Conditioner Modular Design 3

 

Air Supply Method                                                                                                               

Dual Automatic Switching Function Cyber Master CCU Air Conditioner Modular Design 4

 

Technical Parameters                                                                              

                                        

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

  

Case                                                                                                        

                                            