Product Details
Place of Origin: China
Brand Name: Coolnet
Certification: CE/ISO9001
Model Number: M22
Payment & Shipping Terms
Minimum Order Quantity: 1Unit
Price: $1000.00-5000.00/set
Packaging Details: WOODED
Delivery Time: 20-40 days
Payment Terms: T/T, L/C
Supply Ability: 1000-5000/set/month
Color: |
Black/Grey White/other Custom Colors |
Mounting: |
Floor Standing |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Application: |
Data Center, IT Room , Computer Room, Cold/hot Aisle |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Product: |
Precision Air Conditioning Unit/ Data Center Cooling Unit /computer Room Unit /close Control Unit |
Color: |
Black/Grey White/other Custom Colors |
Mounting: |
Floor Standing |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Application: |
Data Center, IT Room , Computer Room, Cold/hot Aisle |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Product: |
Precision Air Conditioning Unit/ Data Center Cooling Unit /computer Room Unit /close Control Unit |
Dual Automatic Switching Function Cyber Master CCU Air Conditioner
Products Introduction
Cyber Master series constant temperature and humidity precision air conditioner is with modular design, high EER, large screen human-computer interface and intelligent control system. It has options of air-cooled, water-cooled, chilled water and double source cooled. CyberMateTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMateTM meets the cooling demand and reduce the PUE of the data center.
Feature & Benefits
|
![]() |
Advantage
![]() |
Designed to operate 24x7
Pathfinder is designed higher than the industry standards, suited for uninterrupted operation of all-weather under-40 ℃-+55 ℃ ambient conditions.
Intelligent control technology
Advanced intelligent control technology, Chinese/ English Large LCD backlit display, easy-to-human interface, precise microcomputer control system; can store 250 historical alarm information. With filter cleaning time alerts.
Phase sequence protection and Phase sequence fault tolerance
Phase sequence protective capability can realize the real-time detection of three-phase power. When the air conditioning fails to work in stable conditions due to phase absence,phase loss and phase sequence unbalance, the protector will make the air conditioning a mandatory stop to protect the unit itself.The sequence fault tolerance function allows self-identification and automatic conversion of phase sequence,ensuring the efficient and safe running of CRAC. No need for manual regulation.
Power failure memory and auto restarting
When power is re-supplied after a power failure, the air conditioning will continue to work in the previous mode set before the interruption of power.
|
Applications
Computer room and data center Switch room and mobile center station in telecommunication High-tech environment and lab Industrial automation control room and precision manufacturing workshop Standard test room and calibration center UPS and battery room Test room in hospital Biochemical culture chamber |
|
Air Supply Method
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |
Case