Unified Management Fan Cooling Container Data Center

Basic Information
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE,ISO
Model Number: CBMC
Minimum Order Quantity: 1unit
Price: 10000-50000USD per unit
Packaging Details: Standard shipping 20 ft 40 ft container with classification society certification
Delivery Time: 20-40 Days
Payment Terms: L/C, T/T
Supply Ability: 50 unit per month
Detail Information
Model: CBMC Miner Type: Antminer Avalon
Power Input: 380V, 220v, 3phase Maximum Capacity: 400 Units Miner
Cooling: Fan Cooling Size: 20FT 40FT
High Light:

380V Container Data Center

,

ISO Approved Container Data Center


Product Description

Unified Management For Fan Cooling Container Data Center

 

Product Introduction                                                                 

 Compared with traditional data centers, the scalability of container data centers has become a major highlight. The administrator of the data center only needs to place the corresponding number of containers in place according to the different needs of users, and connect to the public power and carrier network to complete the expansion of the network.

Modular construction mode, power distribution, cooling and other infrastructure fully adopts modular technology, relying on business demand flexible planning, and convenient flexible expansion when business development needs. Intelligent management system real-time centralized monitoring and unified management of power, environment, security and other systems, the use of flexible expansion of the physical architecture and modular design ideas, both for the management of a single server room infrastructure, but also for the centralized and unified management of multiple sub-geographic server room infrastructure.

 

 

 

 

 

 

Benefits                                                                                      

Unified Management Fan Cooling Container Data Center 0

Unified Management Fan Cooling Container Data Center 1

 

Feature                                                                                        

Unified Management Fan Cooling Container Data Center 2   The container data center is similar to the modular data center and also has the same characteristics of fast deployment. The difference from a modular data center is that its infrastructure granularity can be adjusted according to business growth needs. Each container can be designed as a complete data room, or designed as different subsystems according to power distribution, cooling, fire protection, IT, etc., and spliced to form a data center. Regardless of the form of deployment, the equipment placement pattern, power distribution, HVAC, fire protection, weak power and other systems in the container are prefabricated in the factory using uniform standards. Usually a complete container data center deployment cycle is about 3 months, even if the containers are spliced according to the design architecture of building-type data center, its construction cycle will have obvious advantages.

 

 

Advantage                                                                                   

1, Big power fan, good effect of heat dissipation,, no high humidity.

2, Large air inlet area, heat transfer efficiency is guaranteed.

3. Can be customized

4, Rapid deployment

5, Standard 20 feet 40 feet container size, high intensity, which is suitable for ordinary container shipping.

Unified Management Fan Cooling Container Data Center 3

 

Technical Parameter                                                                 

 

PRODUCT PARAMETERS ICDC-20 ICDC-20
Container Size 20’HQ 40’HQ
Rack Specification 600*1000(1100)*2000mm 600*1000(1100)*2000mm
Single Rack Capacity 42U 42U
Rack Quantity 4PCS 8-10PCS
Single Rack Capacity 3-10KW 3-10KW
IT Equipment Total Capacity 12-30kw 24-75KW
UPS 25kva*2 N+1 modular UPS 25kva*4 N+1 modular UPS
Battery back up time 5-15mins 5-20mins
Cooling In-row air conditioner In-row air conditioner
Monitoring system YES YES
Door Security System YES YES
Fire alarm and gas fire extinguishing system YES YES
Video Monitoring System YES YES
EPO YES YES
Transportability Support Support
Stackable Support Support
Application Outdoor Type Outdoor Type
Diesel Generator Module Extraposition Extraposition

 