Product Details
Place of Origin: CHINA
Brand Name: Coolnet
Certification: ISO,CE,CSC
Model Number: CDC20,CDC40
Payment & Shipping Terms
Minimum Order Quantity: 1set
Price: USD20000-150000/set
Packaging Details: Standard shipping 20 ft 40 ft container with classification society certification
Delivery Time: 20-40days
Payment Terms: L/C,, T/T
Supply Ability: 30 units per month
Size: |
6058*2438*2896mm,12192*2438*2896mm |
Environment Temperature: |
-15-+52℃ |
Environmental Humidity: |
5%-100% |
Power Input: |
2 City Power+ 1 Generator, Or 1 City Power +1 Generator |
Voltage And Frequency: |
3phase 220V,380V, 50/60HZ |
Total Rack Capacity: |
12-75KW |
Rack Quantities: |
4-10PCS |
UPS: |
N+1 ,20-100KVA |
Cooling: |
DX Type In-row Air Conditioner |
Contaiment: |
Cold/hot Aisle |
Size: |
6058*2438*2896mm,12192*2438*2896mm |
Environment Temperature: |
-15-+52℃ |
Environmental Humidity: |
5%-100% |
Power Input: |
2 City Power+ 1 Generator, Or 1 City Power +1 Generator |
Voltage And Frequency: |
3phase 220V,380V, 50/60HZ |
Total Rack Capacity: |
12-75KW |
Rack Quantities: |
4-10PCS |
UPS: |
N+1 ,20-100KVA |
Cooling: |
DX Type In-row Air Conditioner |
Contaiment: |
Cold/hot Aisle |
Prefabricated Containerized Data Center All In One Data Center Solutions
Product Introduction
What is the difference between container data center and modular data center is that the granularity of its infrastructure can be adjusted according to the needs of business growth. Each container can be designed as a complete data room, or it can be designed into different subsystems according to power distribution, cooling, fire protection, IT, etc., and spliced to form a data center. Regardless of the form of deployment, the equipment placement pattern, power distribution, HVAC, fire protection, weak power and other systems in the container are prefabricated in the factory using uniform standards. Usually a complete container data center deployment cycle is about 3 months, even if the containers are spliced according to the design architecture of building-type data center, its construction cycle will have obvious advantages.
Benefits |
![]() |
Feature
![]() |
Low cost Low-cost building materials and construction methods reduce costs for users of containerized data centers and prefabricated units. In some countries or regions, adopters also benefit from tax and regulatory incentives. Hybrid customers (using containerized data centers in traditional data centers) share data center space with other data centers, resulting in cost savings. Green and Energy Efficient Containerized data centers are manufactured in T-factories, with more compact interiors and closed hot and cold aisles for high cooling efficiency. Easy to expand If needed, more space can be added, as shown by adding containerized data centers, prefabricated units or building volumes. |
Advantange
Container modular data center is a standard 20 'and 40' high volume regular container,.Its main advantages:
|
![]() |
Technical Parameter
PRODUCT PARAMETERS | ICDC-20 | ICDC-20 |
Container Size | 20’HQ | 40’HQ |
Rack Specification | 600*1000(1100)*2000mm | 600*1000(1100)*2000mm |
Single Rack Capacity | 42U | 42U |
Rack Quantity | 4PCS | 8-10PCS |
Single Rack Capacity | 3-10KW | 3-10KW |
IT Equipment Total Capacity | 12-30kw | 24-75KW |
UPS | 25kva*2 N+1 modular UPS | 25kva*4 N+1 modular UPS |
Battery back up time | 5-15mins | 5-20mins |
Cooling | In-row air conditioner | In-row air conditioner |
Monitoring system | YES | YES |
Door Security System | YES | YES |
Fire alarm and gas fire extinguishing system | YES | YES |
Video Monitoring System | YES | YES |
EPO | YES | YES |
Transportability | Support | Support |
Stackable | Support | Support |
Application | Outdoor Type | Outdoor Type |
Diesel Generator Module | Extraposition | Extraposition |