Prefabricated Containerized Data Center All In One Data Center Solutions

Product Details

Place of Origin: CHINA

Brand Name: Coolnet

Certification: ISO,CE,CSC

Model Number: CDC20,CDC40

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: USD20000-150000/set

Packaging Details: Standard shipping 20 ft 40 ft container with classification society certification

Delivery Time: 20-40days

Payment Terms: L/C,, T/T

Supply Ability: 30 units per month

Get Best Price
Highlight:

3phase All In One Data Center

,

All In One Modular Data Center Container

,

All In One Data Center 380V

Size:
6058*2438*2896mm,12192*2438*2896mm
Environment Temperature:
-15-+52℃
Environmental Humidity:
5%-100%
Power Input:
2 City Power+ 1 Generator, Or 1 City Power +1 Generator
Voltage And Frequency:
3phase 220V,380V, 50/60HZ
Total Rack Capacity:
12-75KW
Rack Quantities:
4-10PCS
UPS:
N+1 ,20-100KVA
Cooling:
DX Type In-row Air Conditioner
Contaiment:
Cold/hot Aisle
Size:
6058*2438*2896mm,12192*2438*2896mm
Environment Temperature:
-15-+52℃
Environmental Humidity:
5%-100%
Power Input:
2 City Power+ 1 Generator, Or 1 City Power +1 Generator
Voltage And Frequency:
3phase 220V,380V, 50/60HZ
Total Rack Capacity:
12-75KW
Rack Quantities:
4-10PCS
UPS:
N+1 ,20-100KVA
Cooling:
DX Type In-row Air Conditioner
Contaiment:
Cold/hot Aisle
Prefabricated Containerized Data Center All In One Data Center Solutions

Prefabricated Containerized Data Center All In One Data Center Solutions

 

Product Introduction                                                                      

 What is the difference between container data center and modular data center is that the granularity of its infrastructure can be adjusted according to the needs of business growth. Each container can be designed as a complete data room, or it can be designed into different subsystems according to power distribution, cooling, fire protection, IT, etc., and spliced to form a data center. Regardless of the form of deployment, the equipment placement pattern, power distribution, HVAC, fire protection, weak power and other systems in the container are prefabricated in the factory using uniform standards. Usually a complete container data center deployment cycle is about 3 months, even if the containers are spliced according to the design architecture of building-type data center, its construction cycle will have obvious advantages.

 

 

 

Benefits                                                                                              

Prefabricated Containerized Data Center All In One Data Center Solutions 0

Prefabricated Containerized Data Center All In One Data Center Solutions 1

 

Feature                                                                                                

Prefabricated Containerized Data Center All In One Data Center Solutions 2
Low cost
Low-cost building materials and construction methods reduce costs for users of containerized data centers and prefabricated units. In some countries or regions, adopters also benefit from tax and regulatory incentives. Hybrid customers (using containerized data centers in traditional data centers) share data center space with other data centers, resulting in cost savings.
Green and Energy Efficient
Containerized data centers are manufactured in T-factories, with more compact interiors and closed hot and cold aisles for high cooling efficiency.
Easy to expand
If needed, more space can be added, as shown by adding containerized data centers, prefabricated units or building volumes.

 

Advantange                                                                                       

Container modular data center is a standard 20 'and 40' high volume regular container,.Its main advantages:

 

  • Can be customized according to customer's requirements
  • Provide similar data center friendly operation environment
  • Any hardware manufacturers products can be integrated
  • Global maintenance standard integration
  • Extensible modular solution that allows to expand in the future
  • Focus on security (anti invasion, waterproof, fire prevention, and electromagnetic, etc.)Energy efficiency (PUE according to design will be as low as 1.2)
  • Lower TCO
  • Can be used in indoor and outdoor (including oil and gas fields, desert, etc.)
  • Cabinet maximum power for 10 kw/rack
Prefabricated Containerized Data Center All In One Data Center Solutions 3

 

Technical Parameter                                                                        

 

PRODUCT PARAMETERS ICDC-20 ICDC-20
Container Size 20’HQ 40’HQ
Rack Specification 600*1000(1100)*2000mm 600*1000(1100)*2000mm
Single Rack Capacity 42U 42U
Rack Quantity 4PCS 8-10PCS
Single Rack Capacity 3-10KW 3-10KW
IT Equipment Total Capacity 12-30kw 24-75KW
UPS 25kva*2 N+1 modular UPS 25kva*4 N+1 modular UPS
Battery back up time 5-15mins 5-20mins
Cooling In-row air conditioner In-row air conditioner
Monitoring system YES YES
Door Security System YES YES
Fire alarm and gas fire extinguishing system YES YES
Video Monitoring System YES YES
EPO YES YES
Transportability Support Support
Stackable Support Support
Application Outdoor Type Outdoor Type
Diesel Generator Module Extraposition Extraposition

 

Factory View                                                                                      