Micro Data Center Server Precision Air Conditioning Unit Rack mounting

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: CI05,09

Payment & Shipping Terms

Minimum Order Quantity: 1Unit

Price: $500.00-5000.00/set

Packaging Details: WOODED

Delivery Time: 15-30Days

Payment Terms: T/T, L/C

Supply Ability: 1000-5000/set/month

Get Best Price
Highlight:

Micro Data Center Precision Ac Unit

,

Server Rack Precision Ac Unit

,

Server Rack Precision Air Conditioning

Cooling Capacity:
3.5KW-12.5KW
Mounting:
Rack Mounting
Power:
1N-220V-50Hz,110v/50hz/60hz
Air Flow:
750-1100M3/H
Application:
Cabinet/ Intelligent Project And Medium & Small Sized Enterprise
Type:
Split
Cooling Capacity:
3.5KW-12.5KW
Mounting:
Rack Mounting
Power:
1N-220V-50Hz,110v/50hz/60hz
Air Flow:
750-1100M3/H
Application:
Cabinet/ Intelligent Project And Medium & Small Sized Enterprise
Type:
Split
Micro Data Center Server Precision Air Conditioning Unit Rack mounting

Micro Data Center Server Rack Precision Air Conditioning

 

Introduction                                      

Coolnet server rack precision air conditioning provides a flexible and efficient cooling solution for data center interiors. It uses a rack-mounted design concept that is flexible, compact, and suitable for internal circulation cooling inside the cabinet, integrating a separate micro data center with the primary equipment inside the cabinet. The indoor part is installed at the bottom of the cabinet and can adapt itself to the load changes inside the cabinet. The unit adopts air-cooled heat dissipation, environmentally friendly refrigerant, a DC inverter compressor, and a three-speed adjustable internal fan to achieve a high energy efficiency ratio and high apparent heat ratio operation of the whole machine.

 

Benefits                                              

Micro Data Center Server Precision Air Conditioning Unit Rack mounting 0

Micro Data Center Server Precision Air Conditioning Unit Rack mounting 1

Micro Data Center Server Precision Air Conditioning Unit Rack mounting 2

Advantages                                          

Micro Data Center Server Precision Air Conditioning Unit Rack mounting 3

 

                     
  • Embedded in the cabinet design, occupying little space, saving the area of the server room and reducing space cost for customers.
  • Close to heat source cooling, zero loss of cooling capacity, reduced energy consumption, and improved efficiency.
  • DC inverter compressor, dynamic cooling, steplessly adjustable cooling capacity, matching IT load operation Pull-out design, easy installation, and maintenance save operation and maintenance costs.
  • Can be placed in any cabinet, flexible and suitable for various needs of customers.The building and maintenance are flexible and efficient.
                 

Micro Data Center Server Precision Air Conditioning Unit Rack mounting 4

Air Supply Method                                           

Micro Data Center Server Precision Air Conditioning Unit Rack mounting 5

 

Indoor Unit Parameters                                   

Model-CJA 0003 0005 0007 0012
Phase/Function 1.5P,Single Phase 2P,Single Phase 3P,Single Phase 5P,Single Phase
Parameters
Cooling capacity kW 3.5 5 7.5 12.5
Sensible cooling capacity k W 3.5 5 7.5 12.5
Air volume m³/h 800 1150 1600 2300
Sensible heat ratio % 100 100 100 100
Heating kW (Option) 1 1 2 3
Maximum operating current A 15 15 25 34
Power Cord Cable Specifications mm 3×2.5 3×2.5 3×4 3×6
Indoor/outdoor unit shut-off valve
Refrigerant gas pipe φ mm 12.7 12.7 12.7 15.88
Refrigerant liquid pipe φ mm 9.52 9.52 9.52 9.52
Indoor unit structural parameters
Dimension:W×D×H mm 442×714×175 (4U)
442×714×218 (5U)
442×714×218 (5U) 442×714×351 (8U) 442×714×440 (10U)
Outdoor Unit
Type-CJT 3005 3005 3008 3013
Quantity 1 1 1 1
Note 1: Under standard conditions, the indoor dry bulb temperature is 37°C, the wet bulb temperature is 21°C, and the outdoor dry bulb temperature is 35°C;
Note 2: The above table is only part of the parameters, the specific configuration is subject to the actual purchase of the nameplate.

 

Outdoor Unit Parameters                                          

Type- CJT 3005 3005 3008 3013
Power supply 220Vac/1Ph/50Hz
Installation Vertical
Speed mode Stepless speed regulation
Noise dBA 54 55 56 58
Rated current A 6 6 10 15
Power Cord Cable Specifications mm 4×1.5 4×1.5 4×2.5 4×4
Communication cable specificati mm (with shielding function) on 3×1 3×1 3×1 3×1
Structural parameters of outdoor unit
Dimension:W×D×H mm 840×285×610 840×285×610 880×360×800 930×390×1270

① The power cord of the outdoor unit must be connected from the indoor unit;

②The ex-factory unit is not equipped with a 4.3-inch touch screen, and needs to be purchased separately.
 