Direct Cooling Containerized Data Center With Flexible Expansion

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: CBMC

Payment & Shipping Terms

Minimum Order Quantity: 1unit

Price: 10000-50000USD per unit

Packaging Details: FCL

Delivery Time: 20-40 days

Payment Terms: L/C, T/T

Supply Ability: 50 unit per month

Get Best Price
Highlight:

Containerized Data Center Flexible Expansion

,

Direct Cooling Containerized Data Center

,

Direct Cooling Container Data Center

Model:
CBMC
Miner Type:
Antminer Avalon
Power Input:
380V, 220v, 3phase
Maximum Capacity:
400 Units Miner
Cooling:
Fan Cooling
Size:
20FT 40FT
Model:
CBMC
Miner Type:
Antminer Avalon
Power Input:
380V, 220v, 3phase
Maximum Capacity:
400 Units Miner
Cooling:
Fan Cooling
Size:
20FT 40FT
Direct Cooling Containerized Data Center With Flexible Expansion

Containerized Data Center With Flexible Expansion And Direct Cooling

 

 

Product Introduction                                                                      

 
In contrast to the traditional data center construction mode based on the building body, the container-level data center takes the commercial standard container as the carrier of the data center and integrates all systems such as cabinets, power distribution, refrigeration, integrated wiring, monitoring and management, fire protection and security, etc. It adopts the production mode of factory prefabrication and pre-commissioning, transports the container as a whole to the deployment site by land or sea, and then builds it on site in the way of "building blocks". It can be built in the way of "building blocks" and can be operated independently by accessing utility power, network and water source, thus making the deployment of data center more mobile and flexible.
Direct Cooling Containerized Data Center With Flexible Expansion 0

 

 

Feature                                                                                         

Direct Cooling Containerized Data Center With Flexible Expansion 1
  • High modular degree, simple structure, convenient for transportation, installation and maintenance;
  • According to the properties of the selected batteries, choose the specialized Intelligent BMS;
  • The system is equipped with local and remote monitor system, implementing real-time online control;
  • Bilingual contrast
  • Adopt air cooling mode, optimize the air distribution, implement intelligent control, save temperature control energy consumption, temperature field is uniform ;
  • With complete safety protection measures to ensure operation personnel and energy storage system safe and work reliably.
  • As per the customer requirement and load character provide the custom design solution,
  • Base on the system requirement, adopt the specialized energy storage battery Lead acid, Gel, Lead carbon or lithium ion battery, configure energy storage units flexibly;

 

 

Advantage                                                                                    

 Customized Engineering, Rapid Deployment
Modular data centers can be deployed very quickly, with traditional civil buildings replaced by light steel structures or storage warehouses, with construction cycles typically taking only a few weeks, compared to months, or even years, to build a traditional data center. Also, with modular container products, product quality can be fully guaranteed.


Low cost
Low-cost building materials and construction methods reduce costs for users of containerized data centers and prefabricated units. In some countries or regions, adopters also benefit from tax and regulatory incentives. Hybrid customers (using containerized data centers in traditional data centers) share data center space with other data centers, resulting in cost savings.


Green and Energy Efficient
Containerized data centers are manufactured in T-factories, with more compact interiors and closed hot and cold aisles for high cooling efficiency.


Easy to expand
If needed, more space can be added, as shown by adding containerized data centers, prefabricated units or building volumes.

Direct Cooling Containerized Data Center With Flexible Expansion 2

 

Technical Parameter                                                                    

 
PRODUCT PARAMETERS ICDC20 ICDC40
Container Size 20'HQ 40'HQ
Rack Specification 600*1000*2000 600*1000*2000
Single Rack Capacity 42U 42U
Rack Quantity 4pcs 4pcs
Single Rack Max. Capacity 6KW 6KW
IT Equipment Total Capacity 24KW 48KW
UPS 25KVA*2
N+1 Modular UPS
25KVA*3
N+1 Modular UPS
Battery Back-up Time 10Minutes 10Minutes
Cooling Pattern Inrow Air Condition Inrow Air Condition
Monitoring system YES YES
Door Security System YES YES
Fire alarm and gas fire extinguishing system YES YES
Video Monitoring System YES YES
EPO YES YES
Transportability Support Support
Stackable Support Support
Application Outdoor Type Outdoor Type
Diesel Generator Module Extra position Extra position