Constant Temperature & Humidity In Row Precision Air Conditioning For IDC

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: CRA,CRW

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 3000-20000USD/Unit

Packaging Details: Wooded

Delivery Time: 25-30 working days

Payment Terms: T/T, L/C

Supply Ability: 1000Units/Month

Get Best Price
Highlight:

Precision Air Conditioning For IDC

,

In Row Air Conditioning Floor Standing

,

In Row Air Conditioning For IDC

Total Capacity:
26.7 KW (24℃/50%RH)
Power Supply:
380V 3Ph-50HZ
Airflow:
5000 M³/h
Humidifier Capacity:
1.5 Kg/h
Air Filter Level:
≥G4
Outdoor Unit Condenser:
Model:CY0451
Weight:
230 Kgs
Dimension:
300mm*1200mm*2000 Mm 300mm*1400mm*2000 Mm
Total Capacity:
26.7 KW (24℃/50%RH)
Power Supply:
380V 3Ph-50HZ
Airflow:
5000 M³/h
Humidifier Capacity:
1.5 Kg/h
Air Filter Level:
≥G4
Outdoor Unit Condenser:
Model:CY0451
Weight:
230 Kgs
Dimension:
300mm*1200mm*2000 Mm 300mm*1400mm*2000 Mm
Constant Temperature & Humidity In Row Precision Air Conditioning For IDC

Constant Temperature & Humidity Air Conditioner In Row Precision Air Conditioning For IDC

 

Product Introduction                           

 

In row air condition are also known as cool row air conditioning. Placed between the server cabinet columns, the heat source directly cooling equipment, row room precision air conditioner belongs to the mechanical room air conditioning. The heat dissipation of the server and communication equipment in the data center is increasing. Therefore, the cooling method of the forward air conditioner cannot meet the requirements of the equipment for temperature and humidity. In order to effectively cool the equipment and prevent local overheating, cool air must enter the equipment inside the tissue for heat removal.

 

Features & Benefits                              

Constant Temperature & Humidity In Row Precision Air Conditioning For IDC 0

Constant Temperature & Humidity In Row Precision Air Conditioning For IDC 1
 

Structure & Components                        

 

 

 

 

Constant Temperature & Humidity In Row Precision Air Conditioning For IDC 2

 

Efficient EC Fan System

  • Saving 20%-30% energy compared to traditional AC motor
  • Motor soft-startup function, Low startup current
  • Adjust rotary speed automatically according to cooling requirments and airflow pressure, and provide airflow required
  • N+1redundancy configuration of fans, en sure the airflow in case of any fan fault
  • Easy-maintenance designed

 

Easy-maintenance Designed

  • High Efficiency Compressor System
  • R410A refrigerant
  • Adopting scroll compressor with high reliability and energy efficiency ratio

 

Electronic Expansion Valve

  • Adjust the throttle of valve smoothly to save the energy
  • Wide range og operations, which can help reduce the superheat degree and improvde EER Realize cooling capacity and heat load precise matching
  • Quick response, realize the precise cooling

EVO Control System

  • Graphic display, including the running status and the temperature/humidity of the inlet/outlet air.

  • Advanced team work function, up to 32 units and easy to set network.

  • Standard RS485 port, optional SNMP, TCP/IP interfaces, and GPRS with SMS.

  • Standard communication protocol, optional customized specifications.

 

 

 

High Flexibility

  • Air-cooled or chilled water-cooled cooling scheme.
  • Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.
  • High Reliability & Serviceability.
  • 24*7 uninterruptible operation design.
  • 4 Levels of password protection.
  • Service access is via the front or rear of the unit.

 

 

 

Advantages                                   

 

 

 

Constant Temperature & Humidity In Row Precision Air Conditioning For IDC 3

 

 

Technical Parameter                                                                    

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                                                    

Constant Temperature & Humidity In Row Precision Air Conditioning For IDC 4

 

Factory Details                                           

Constant Temperature & Humidity In Row Precision Air Conditioning For IDC 5

 

Packing and Delivery                                       

Constant Temperature & Humidity In Row Precision Air Conditioning For IDC 6

 

Case                                                    

Constant Temperature & Humidity In Row Precision Air Conditioning For IDC 7