Row Based Cooling Unit For Data Center Server Complete Cooling Solution

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE/ISO

Model Number: CRA025

Payment & Shipping Terms

Minimum Order Quantity: 1Unit

Price: USD1,000-10,000/Unit

Packaging Details: Standard export package

Delivery Time: 10-25 working days

Payment Terms: T/T, L/C

Supply Ability: 1000Unit/Month

Get Best Price
Highlight:

Computer Room Air Conditioning Unit 63KW

,

Row Based Cooling Unit

,

Air Conditioning Unit Row Based

Power Supply:
220-380V/50-60Hz
Total Capacity:
13-63KW
Air Volume:
5500-12500m³/h
Warranty:
1 Year(12 Month With No Artificial Damage)
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Type:
InRow Unit
Operating Voltage:
380/400 VAC,230 VAC,220V
Application:
Data Center, Computer Room, Server Rooms, Modular Data Centers, Communication Base Station
Power Supply:
220-380V/50-60Hz
Total Capacity:
13-63KW
Air Volume:
5500-12500m³/h
Warranty:
1 Year(12 Month With No Artificial Damage)
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Type:
InRow Unit
Operating Voltage:
380/400 VAC,230 VAC,220V
Application:
Data Center, Computer Room, Server Rooms, Modular Data Centers, Communication Base Station
Row Based Cooling Unit For Data Center Server Complete Cooling Solution

Row-Based Cooling Unit for Data Center Server Complete Cooling Solution

 
 

Product Introduction                                                

 

COOLNET Row Cooling Precision Air Conditioning is an ideal product for inter-column cooling in green data centers. It has the industry's best cooling efficiency. The variable frequency scroll compressor uses environmentally friendly refrigerant R410A. It has excellent intelligent control and performance. Flexible cooling capacity design: can be used in 20%~100% adjustment of cooling capacity, which greatly improves the energy efficiency of ordinary air-cooled units by 33.3%~50%. The 7-inch touch screen can comprehensively display various data in the computer room and related working conditions of the unit

 

Advantages                                                             

 

 

Efficient EC fan system

  • Saving 20%-30% energy compared to traditional AC motor
  • Soft-startup function, Low startup current
  • Adjust rotary speed automatically according to cooling requirments and airflow pressure,and provide airflow required
  • N+1redundancy configuration of fans, ensure the airflow in case of any fan fault
  • Easy-maintenance designed

 

Options

  • Transfer switch for Dual Power Input
  • GPRS SMS alarm
  • Low-temperature startup kits
  • Wired Temperature/humidity sensors
  • Tree-way water valv

 

Electronic Expansion Valve

  • Adjust the throttle of valve smoothly to save the energy
  • Wide range og operations, which can help reduce the superheat degree and improvde EER
  • Realize cooling capacity and heat load precise matching
  • Qucik response, realize the precise cooling

 

Row Based Cooling Unit For Data Center Server Complete Cooling Solution 0

 

Air Supply Method                                                 

 

R410A Inrow Cooling Unit For Modular Data Center  Cooling 1 R410A Inrow Cooling Unit For Modular Data Center  Cooling 2

 

Technical Parameter                                                          

               

Model CRA013 CRA025 CRA040 CRA050 CRA060
Air Supply Front/Side Front/Side Front/Side Front/Side Front/Side
Power Supply 380Vac/3Ph/50Hz 380Vac/3Ph/50Hz 380Vac/3Ph/50Hz 380Vac/3Ph/50Hz 380Vac/3Ph/50Hz
Technical Data
Cooling Capacity (kW) 13.2 26.7 42.6 53.3 63. 9
Sensible Cooling (kW) 13.2 26.7 42.6 53.3 63. 9
Compressor
Refrigerant R410A R410A R410A R410A R410A
Quantity 1 1 1 1 1
Fan
Fan Type EC centrifugal fan EC centrifugal fan EC centrifugal fan EC centrifugal fan EC centrifugal fan
Quantity 4 5 2 3 3
Air Volume (m3/h) 3200 5000 8800 11000 12500
Heater
Heat Type PTC PTC PTC PTC PTC
Capacity (kW) 2 3 6 6 6
Class 1 1 1 1 1
Humidification
Type Electrode type
Capacity (kg/h) 1 1.5 3 3 3
Air Filter G4 G4 G4 G4 G4
Connection Pipe
Humidifier inlet pipe (in) G1/2 G1/2 G1/2 G1/2 G1/2
Drain Pipe Φ (mm) 25 19 19 19 19
Gas Pip Φ(mm) 15.88 19.05 19.05 22 22
Liquid Pipe Φ (mm) 9.52 12.7 15.88 19.05 19.05
           
Indoor Dimension-L*D*H (mm)
Dimension 300*1200*2000
300*1400*2000
300*1200*2000
300*1400*2000
600*1200*2000 600*1200*2000 600*1200*2000
Weight (kg) 190 230 285 310 330
Note:
Standard working conditions: indoor return air dry bulb temperature 37°C, relative humidity 24%, outdoor dry bulb temperature 35°C ;

 