Home > products > Computer Room Air Conditioning Unit > Computer Server Room Precision Air Conditioner Constant Temperature And Humidity

Computer Server Room Precision Air Conditioner Constant Temperature And Humidity

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYDS40D/U

Payment & Shipping Terms

Minimum Order Quantity: 1Unit

Price: USD3,000-10,000/Unit

Packaging Details: Standard Export Package

Delivery Time: 20-45 working days

Payment Terms: T/T, L/C

Supply Ability: 1000Unit/Month

Get Best Price
Highlight:

Computer Server Room Precision Air Conditioner

,

26kw Computer Room Air Conditioning Unit

,

Constant Humidity Server Room Air Conditioner

Cooling Capacity:
26-102KW
Operating Voltage:
380V 3Ph-50HZ
Fan Section:
Centrifugal EC FAN
Compressor:
Copeland Compressor
Refrigerant:
R410A
Color:
Customized Colors
Airflow:
Upflow/Downflow
Working Temperature Ranger:
-40℃~+55℃
Cooling Capacity:
26-102KW
Operating Voltage:
380V 3Ph-50HZ
Fan Section:
Centrifugal EC FAN
Compressor:
Copeland Compressor
Refrigerant:
R410A
Color:
Customized Colors
Airflow:
Upflow/Downflow
Working Temperature Ranger:
-40℃~+55℃
Computer Server Room Precision Air Conditioner Constant Temperature And Humidity

Constant temperature and humidity Computer Server Room Precision Air Conditioner

 

Product Introduction                                         

 

Coolnet focuses on the R&D, production, and application of data center integrated solutions. As technical consulting, product supply, system integrator, and service provider, it is committed to serving customers in the fields of communication equipment rooms, data centers, smart construction, and energy management.

      

CyberMaster series precision air conditioning system adopts international cutting-edge constant temperature and constant humidity technology, which is designed and developed for a precision environment.

 

 

Advantages                                                     

 

  • 7" color touch controller, easy and convenient to operate
  • With 3 levels of password, set different operation levels
  • Standard RS485 interface, flexible networking monitoring mode
  • With 500 large capacity fault alarm records storage function
  • Can display the whole machine and parts running status and running time
  • All-day running design can guarantee the main equipment safe operation.
  • All parts had passed severe test and confirmed stable and reliable before delivery.
  • High energy efficiency
  • Sensible heat ratio is up to 91%.
  • Compressor energy efficiency ratio is over 3.1, and chilled water
  • cooled unit’s cooling energy efficiency is larger than 25.
  • The optimal and high efficiency compressor and fans.

Computer Server Room Precision Air Conditioner Constant Temperature And Humidity 0

          

Technical Features                                         

             

Computer Server Room Precision Air Conditioner Constant Temperature And Humidity 1

Fan

Use the efficient and low-noise EBM backward tilt centrifugal wind motorized balance test to ensure long life, high energy efficiency, low energy consumption and low noise operation. Compared with equipment with the same air volume in the industry, the power consumption is the lowest.

 

Condenser

The air-cooled condenser is made of marine grade corrosion-resistant materials, has outstanding rigidity and anti-corrosion functions, and is accustomed to various environmental conditions. Fully adjustable speed electric fans are used to achieve energy saving and low noise.

 

Air pressure switch

Configurable filter blockage and airflow loss are two functions of the air pressure switch for accurate monitoring of filter status and fan status to ensure normal operation of the unit.

 

Compressor

Copeland flexible scroll compressor with high efficiency, optional Danfoss EC compressor, which can regulate cooling capacity from 10% to 100%, can dynamically output cooling capacity according to demand, energy saving,

and high efficiency.

 

Technical Parameters                                       

 

Model: CYD S26D/U S31D/U S35D/U S40D/U S45D/U T41D/U T50D/U T55D/U T61D/U T70D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
DX Total Capacity KW 26.8 31.5 35.5 40.2 45.6 41.9 50.5 55.4 61.4 70.5 85.5 90.8 102
Sensible KW 24.2 28.9 33.2 37.6 42.2 38.8 47.8 51.6 57.5 65.2 79.5 84.5 95.7
AEER W/W 3.6 3.7 3.7 3.7 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6
CW water inlet/outlet T7/12℃
Total Capacity KW 33.6 33.6 44.2 44.2 56.4 44.2 56.4 59.1 73.5 76.4 89.2 92.5 92.5
Sensible KW 29.2 29.2 37.7 37.7 48.6 37.7 48.6 51.2 63.2 66 77.8 81.7 81.7
Flow Rate m3/h 5.8 5.8 7.6 7.6 9.7 7.6 9.7 10.1 12.6 13.1 15.3 15.9 15.9
Compressor Hermetic scroll
Refrigerant R410A
Compressor quantity PC 1 1 1 1 1 2 2 2 2 2 2 2 2
Fan Section Centrifugal EC fan
Airflow m3/h 7800 9200 9800 10600 12000 11500 15500 16000 17500 18500 22500 23500 24200
Fan quantity PC 2 2 2 2 2 2 2 2 2 2 3 3 3
Rated current A 2.8 3.5 4.1 4.4 4.9 4.4 4.4 5 5.2 5.2 16.5 16.5 16.5
Rated power W 1200 1320 2000 2150 2400 1800 2000 3000 3300 3900 5400 6300 6300
Excess press outside(2) Pa 20-300 Adjustable
Air filter Standard EN799
Level ≥G4
Dust interception rate >95%
Fire resistance level 1
Reheat Section
Total heating capacity KW 6 6 6 9 9 9 9 9 9 9 15 15 15
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 13 13 13 13 13 13 13 13 13 13
Physical
Length mm 915 915 915 1315 1315 1315 1315 1315 1790 1790 2190 2190 2190
Depth mm 980 980 980 980 980 980 980 980 980 980 980 980 980
Height mm 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975
Weight KG 393 490 590 595 610 605 615 620 625 625 985 992 1015
Connection Pipe Size
Liquid pipe mm 22 22 28 28 28 22 22 22 22 28 28 28 28
Gas Pipe mm 28 28 35 35 35 28 28 28 28 35 35 35 35
Inlet Pipe of Humidifier(Female)   G1/2'' G1/2'' G1/2'' G1/2'' G1/2'' G1/2'' G1/2'' G1/2'' G1/2'' G1/2'' G1/2'' G1/2'' G1/2''
Drain Pipe-ID mm 25 25 25 25 25 25 25 25 25 25 25 25 25
Breakers & Cables
Recommended Breaker (Indoor Unit) A 50 50 63 80 80 80 80 100 100 125 150 150 150
Cableds (Indoor Unit) mm2 4*10+1*6 4*10+1*6 4*10+1*6 4*10 4*16+1*10 4*16+1*10 4*16+1*10 4*16+1*10 4*16+1*10 3*25+2*16 3*25+2*16 3*50+2*25 3*50+2*25