Product Details
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE,ISO
Model Number: CNER-1101(L), CNER-1102(L), CNER-1103(L), CNER-1106L, CNER-1110L
Payment & Shipping Terms
Minimum Order Quantity: 5units
Price: Contact us for a model-specific quotation
Packaging Details: Export carton packing
Delivery Time: To be confirmed by configuration
Payment Terms: L/C,T/T,Western Union
Supply Ability: Please confirm with your quotation
Output Voltage: |
200/208/220/230/240VAC |
Type: |
Online Double-conversion Rack UPS |
Application: |
Server Rooms, Network Cabinets And Telecom Equipment |
Phase: |
Single-phase Input And Output |
Waveform: |
Pure Sine Wave |
Frequency: |
50/60Hz |
Rack Height: |
1-3kVA: 88mm; 6-10kVA L Models: 133mm |
Mains/battery Transfer: |
0ms |
Communications: |
RS-232/USB; Optional SNMP |
Rated Capacity: |
1/2/3/6/10kVA; 0.8/1.6/2.4/4.8/8kW |
Output Voltage: |
200/208/220/230/240VAC |
Type: |
Online Double-conversion Rack UPS |
Application: |
Server Rooms, Network Cabinets And Telecom Equipment |
Phase: |
Single-phase Input And Output |
Waveform: |
Pure Sine Wave |
Frequency: |
50/60Hz |
Rack Height: |
1-3kVA: 88mm; 6-10kVA L Models: 133mm |
Mains/battery Transfer: |
0ms |
Communications: |
RS-232/USB; Optional SNMP |
Rated Capacity: |
1/2/3/6/10kVA; 0.8/1.6/2.4/4.8/8kW |
The CNER 1–10kVA range provides online double-conversion power protection for server rooms, network cabinets and telecommunications equipment. Select a model by both its kVA and kW rating, then match the battery configuration to the required backup time.
| Model | Rated Capacity | Long-Backup Dimensions (W * D * H) | Long-Backup Net Weight |
|---|---|---|---|
| CNER-1101 / CNER-1101L | 1kVA / 0.8kW | 438 * 310 * 88mm | 5kg |
| CNER-1102 / CNER-1102L | 2kVA / 1.6kW | 438 * 410 * 88mm | 7kg |
| CNER-1103 / CNER-1103L | 3kVA / 2.4kW | 438 * 530 * 88mm | 8kg |
| CNER-1106L | 6kVA / 4.8kW | 438 * 580 * 133mm | 12kg |
| CNER-1110L | 10kVA / 8kW | 438 * 580 * 133mm | 16kg |
Dimensions and weights in this table apply to the L long-backup variants. Standard 1–3kVA units have different battery arrangements and weights. Product images show representative CNER series configurations; enclosure and battery arrangement vary by selected model.
| Input/Output Phase | Single phase |
|---|---|
| Rated Input and Output Voltage | 200/208/220/230/240VAC |
| Input Voltage Range | 110–300VAC |
| Input Frequency Range | 40–70Hz |
| Output Voltage Regulation | ±1% |
| Output Frequency in Battery Mode | 50Hz ±0.1Hz or 60Hz ±0.1Hz |
| Mains/Battery Transfer | 0ms |
| Inverter/Bypass Transfer | 1–3kVA: up to 4ms; 6–10kVA: 0ms, under catalog conditions |
| Mains and Battery Efficiency | 1–3kVA: at least 91%; 6–10kVA: at least 93% |
| Operating Temperature | 0–40°C |
| Relative Humidity | 0–95%, non-condensing |
For a server or communications cabinet, confirm the connected load in watts and VA, available rack depth, power connections and desired backup duration before ordering. Battery quantity, capacity, cabling and any external battery cabinet must be selected for the specified UPS model. An SNMP card is optional rather than included as standard.
This single-phase listing covers 1, 2, 3, 6 and 10kVA CNER models, with rated real power from 0.8 to 8kW.
No. Mains-to-battery transfer is 0ms. The catalog specifies inverter-to-bypass transfer of up to 4ms for 1–3kVA models and 0ms for 6–10kVA models.
Runtime depends on the selected battery configuration and connected load. Provide both values when requesting a configuration.
No. Rack depth, height and weight vary by capacity and by standard or long-backup configuration. Use the selected model's dimensions.
RS-232/USB communications are provided, and an optional SNMP card supports network management.