Product Details
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE,ISO
Model Number: CNM-100/10, CNM-150/15, CNM-200/20, CNM-250/25, CNM-300/30
Payment & Shipping Terms
Minimum Order Quantity: 1 UNIT
Price: Contact us for a configuration-specific quotation
Packaging Details: Standard export package
Delivery Time: To be confirmed by configuration
Payment Terms: L/C,T/T
Supply Ability: Please confirm with your quotation
Output Voltage: |
380/400/415VAC |
Application: |
Data Centers, Telecom Facilities And Industrial Control Rooms |
Protection: |
Short Circuit,Overcurrent,Overvoltage,overload,Unbalanced Loads |
Type: |
Online Double-conversion Modular UPS |
Phase: |
Three-phase Five-wire Input And Output |
Capacity: |
100/150/200/250/300kVA System Capacity |
Product Name: |
CNM Modular Uninterruptible Power Supply |
Display: |
LCD + LED With Color Touch Screen |
Wave Form: |
Pure Sine Wave |
Input Voltage: |
380/400/415VAC, 50/60Hz |
Module Quantities: |
According To Load And Redundancy Requirement |
Power Module Rating: |
10/15/20/25/30kVA, Depending On Model |
Redundancy: |
Configurable N+1 To N+X |
Output Voltage: |
380/400/415VAC |
Application: |
Data Centers, Telecom Facilities And Industrial Control Rooms |
Protection: |
Short Circuit,Overcurrent,Overvoltage,overload,Unbalanced Loads |
Type: |
Online Double-conversion Modular UPS |
Phase: |
Three-phase Five-wire Input And Output |
Capacity: |
100/150/200/250/300kVA System Capacity |
Product Name: |
CNM Modular Uninterruptible Power Supply |
Display: |
LCD + LED With Color Touch Screen |
Wave Form: |
Pure Sine Wave |
Input Voltage: |
380/400/415VAC, 50/60Hz |
Module Quantities: |
According To Load And Redundancy Requirement |
Power Module Rating: |
10/15/20/25/30kVA, Depending On Model |
Redundancy: |
Configurable N+1 To N+X |
The CNM 100–300kVA selection combines online double-conversion power protection with hot-swappable power modules for data centers, telecommunications facilities, and industrial control rooms. Select the cabinet capacity and module rating together, then reserve sufficient module capacity for the required redundancy level.
| System Model | System Capacity | Power Module | Module Rating |
|---|---|---|---|
| CNM-100/10 | 100kVA | HM10 | 10kVA |
| CNM-150/15 | 150kVA | HM15 | 15kVA |
| CNM-200/20 | 200kVA | HM20 | 20kVA |
| CNM-250/25 | 250kVA | HM25 | 25kVA |
| CNM-300/30 | 300kVA | HM30 | 30kVA |
System capacity and individual module rating are different specifications. Product images show representative CNM cabinet configurations; the cabinet layout and installed modules depend on the selected configuration.
| Input and Output Connection | Three-phase five-wire system |
|---|---|
| Rated Input/Output Voltage | 380/400/415VAC |
| Rated Frequency | 50/60Hz |
| Input Frequency Range | 40–70Hz |
| Output Voltage Accuracy | ±1% |
| Output Power Factor | 1.0 |
| Mains-Mode and Battery-Mode Efficiency | ≥96% |
| ECO-Mode Efficiency | ≥98% |
| Enclosure Protection | IP20; IP21 optional |
| Operating Temperature | −10°C to 40°C |
| Relative Humidity | 0–95%, non-condensing |
Before ordering, confirm the load in kW and kVA, supply voltage, redundancy target, battery backup duration, and installation conditions. Battery capacity and runtime are project-specific. Cabinet dimensions, installed module quantity, protection options, and communications configuration should be confirmed in the final quotation.
It identifies a 200kVA system using HM20 power modules rated at 20kVA each. The number of installed modules must be selected for the actual load and redundancy requirement.
Redundant capacity must be reserved. The usable protected load depends on the installed module capacity and the number of spare modules required by the design.
The series supports hot-swappable modules. Replacement must follow the manufacturer service procedure and be performed by qualified personnel with adequate remaining capacity and the required safety controls.
Runtime depends on load, battery capacity, and battery condition. Provide the required runtime and load profile so the battery configuration can be selected for the project.
No. The listed CNM systems use three-phase five-wire input and output at rated voltages of 380/400/415VAC.