Home > Products > Micro Data Centers > Coolnet MetaRack ER03 Three-Cabinet Micro Data Center with 10kVA UPS, 12.5kW In-Row Cooling, 113U IT Space and 10-Inch Monitoring for Edge Computing

Coolnet MetaRack ER03 Three-Cabinet Micro Data Center with 10kVA UPS, 12.5kW In-Row Cooling, 113U IT Space and 10-Inch Monitoring for Edge Computing

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Model Number: ER03

Payment & Shipping Terms

Minimum Order Quantity: 1PCS

Price: Negotiable

Packaging Details: Standard export package

Delivery Time: 20-35 working days

Payment Terms: L/C,T/T

Supply Ability: 200 SETS PER MONTH

Get Best Price
Highlight:

Three-Cabinet Micro Data Center

,

Micro Data Center with 10kVA UPS

,

Edge Computing Micro Data Center

Product Name:
Micro Data Center
Cabinet Configuration:
1 Combined Cabinet + 2 IT Cabinets
Operating Voltage:
220V / 125A Input
Cooling System:
12.5kW In-row Cooling
Product Name:
Micro Data Center
Cabinet Configuration:
1 Combined Cabinet + 2 IT Cabinets
Operating Voltage:
220V / 125A Input
Cooling System:
12.5kW In-row Cooling
Coolnet MetaRack ER03 Three-Cabinet Micro Data Center with 10kVA UPS, 12.5kW In-Row Cooling, 113U IT Space and 10-Inch Monitoring for Edge Computing
Coolnet MetaRack ER03 Three-Cabinet Micro Data Center

The ER03 integrates one combined cabinet and two IT cabinets with power distribution, a 10kVA rack UPS, 12.5kW in-row cooling, and centralized monitoring. It is designed for compact edge infrastructure and distributed IT deployments.

Key Features
  • 113U total available IT space: 29U plus two 42U cabinets.
  • 10kVA UPS with 0.8 power factor and 220V/125A total power input.
  • 12.5kW in-row precision cooling with compression system and EC fan.
  • Fully enclosed hot and cold aisles help manage airflow.
  • 10-inch touchscreen provides centralized infrastructure monitoring.
Technical Specifications
Item ER03 Configuration
Cabinets 1 combined cabinet + 2 IT cabinets
Available space 29U + 2 x 42U (113U total)
UPS capacity 10kVA, rack type
Power factor 0.8
Total power input 220V / 125A
Cooling 12.5kW in-row, sensible heat ratio 1
Redundancy N, typical configuration
Display 10-inch touchscreen
Dimensions (W x D x H) 2100 x 1200 x 2000 mm
Operating environment 0-45°C; 0-95% relative humidity, non-condensing; below 1000m altitude
Monitoring and Configuration

Monitoring covers UPS, power distribution, air conditioning, water leakage, temperature and humidity, smoke, and door sensors. Functions include data collection and storage, alarm management, energy consumption analysis, and remote access. SMS, app access, sound/light alarms, ATS, and rack-mounted gas fire suppression are optional.

Battery backup duration depends on the selected battery configuration and load. Confirm the project requirements before ordering.

Application and Selection

Suitable for edge computing, branch offices, and distributed server infrastructure where integrated power, cooling, and monitoring are required. Confirm IT load, rack allocation, electrical supply, site dimensions, and required battery autonomy during project selection.