Home > Products > Server Rack Mount Air Conditioner > Coolnet CJA0003 3.5kW 5U Rack Air Conditioner with DC Inverter Compressor and 800 m3/h EC Airflow for Edge IT Cabinets

Coolnet CJA0003 3.5kW 5U Rack Air Conditioner with DC Inverter Compressor and 800 m3/h EC Airflow for Edge IT Cabinets

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: Model-specific compliance documents available on request

Model Number: CJA0003

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $500.00-5000.00/set

Packaging Details: WOODED

Delivery Time: 4W

Payment Terms: T/T,L/C

Supply Ability: 1200-5000/set/month

Get Best Price
Highlight:

5U rack air conditioner

,

DC inverter rack air conditioner

,

800 m3/h EC airflow cooling

Height:
5U
Color:
Black/Grey White/other Custom Colors
Air Flow:
800 M3/h
Voltage:
220V
Application:
Enclosed Server Cabinets And Micro Data Centers
Type:
Split
Mounting:
19-inch Rack Mounting
Cooling Capacity:
3.5kW
Power:
220Vac / 1Ph / 50Hz
Height:
5U
Color:
Black/Grey White/other Custom Colors
Air Flow:
800 M3/h
Voltage:
220V
Application:
Enclosed Server Cabinets And Micro Data Centers
Type:
Split
Mounting:
19-inch Rack Mounting
Cooling Capacity:
3.5kW
Power:
220Vac / 1Ph / 50Hz
Coolnet CJA0003 3.5kW 5U Rack Air Conditioner with DC Inverter Compressor and 800 m3/h EC Airflow for Edge IT Cabinets
Coolnet CJA0003 5U Inverter Rack Cooling for Edge IT Cabinets

Designed for enclosed edge IT cabinets, the Coolnet CJA0003 combines a compact 5U rack-mounted indoor unit with a separate CJT3005 outdoor condenser. The split air-cooled system provides 3.5kW total and sensible cooling with 800 m³/h airflow under the specified rating conditions. Its standard 19-inch rack format places cooling beside the server equipment without occupying additional floor space.

Inverter Cooling with Controlled Cabinet Airflow

A DC inverter compressor and EC centrifugal fan allow cooling output and air delivery to follow cabinet demand. The CJA0003 supports cabinet-level temperature control in micro data centers and modular IT layouts, with fault alarms, protection functions and remote monitoring support. Site selection should account for equipment heat load, rack clearance and the outdoor piping route.

  • Variable-capacity inverter cooling for changing IT heat loads.
  • EC centrifugal fan with demand-based airflow adjustment.
  • Precision cooling controls with fault alarms, protection and remote monitoring support.
  • Front-access maintenance and quick-coupling refrigeration connections simplify service.
  • R410A refrigerant and a separate outdoor condenser.
CJA0003 Technical Specifications
Parameter Specification
Indoor model CJA0003
Total / sensible cooling capacity 3.5kW / 3.5kW
Airflow 800 m³/h
Sensible heat ratio 100% at rated conditions
Indoor dimensions (W * D * H) 442 * 714 * 218 mm (5U)
Installation Inside a standard 19-inch rack
System type Split, air-cooled precision cooling
Power supply 220Vac / 1Ph / 50Hz
Maximum operating current 15A
Matched outdoor unit CJT3005, quantity 1
Outdoor dimensions (W * D * H) 840 * 285 * 610 mm
Optional heating 1kW

Rating conditions: indoor dry-bulb 37°C, wet-bulb 21°C, and outdoor dry-bulb 35°C. Capacity and dimensions must be checked against the selected configuration and equipment nameplate.

Applications and Installation Planning

Designed for enclosed micro data center cabinets, single-row IT cabinets and modular computer-room projects. Confirm the cabinet's available rack space, equipment heat load, airflow path, condenser position, piping route and drainage arrangement before selection. The outdoor unit is powered from the indoor unit. A 4.3-inch touchscreen is an optional accessory and is not included as standard.

Frequently Asked Questions
Is this an integrated all-in-one unit?

No. The CJA0003 uses a rack-mounted indoor unit paired with one CJT3005 outdoor condenser.

How much rack height is required?

The listed indoor configuration occupies 5U, with dimensions of 442 * 714 * 218 mm.

Can the cooling output follow changes in IT load?

The inverter refrigeration system and EC fan support adjustment to cooling demand. Final selection should account for the actual site conditions.