Name: |
Data Center Rack Cold Aisle Containment |
Color: |
Grey Or Black |
Material: |
2.0mm Cold Rolled Steel |
Two Ends Doors:: |
Sliding /manual Doors Optional |
Hot Air Containment: |
Included |
Static Payload: |
1100kg |
Cabinet Standard:: |
ANS/EIA RS-310-D |
Custom Logo Lable: |
Yes |
Name: |
Data Center Rack Cold Aisle Containment |
Color: |
Grey Or Black |
Material: |
2.0mm Cold Rolled Steel |
Two Ends Doors:: |
Sliding /manual Doors Optional |
Hot Air Containment: |
Included |
Static Payload: |
1100kg |
Cabinet Standard:: |
ANS/EIA RS-310-D |
Custom Logo Lable: |
Yes |
Data Center High Density Micro Modular Data Centers Cold Aisle Containment Solutions
Product Introduction Coolnet mini-modular data center can flexibly adopt the layout of double-row cabinets + cold/hot aisle or single-row cabinets + cold/hot aisle according to user site conditions. Under the two structural layouts, all subsystems such as cabinets, channels, power supply and distribution, refrigeration, security, environmental monitoring and management, and wiring can be integrated according to user needs, providing customers with new data of rapid deployment, high efficiency and energy saving, compact space, and flexible expansion Central solution.
Advantages
|
Characteristics
Modular design Modular and self-contained closed design. The two cabinet in both sides of hot or cold aisle are one unit,can be installed seperatedly,provide scalable solutions as demand change or grow. Intelligent Intelligent fire control can be implemented for every top plate. Once fire signal alarm in room, the top plate will open automatically,and fire extinguishing gases can enter the aisle. Convinence No threshold design,convinent for wheelbarrow. Aesthetic The window is made of prespective tempering glass with high mechanical strenth,good permeability.The Black coating of cold rolled steel plate borders and cabinet style is consistent and also coorinated with the computer room. Automatical door structure The sliding door can be closed automatically,can be installed door access system and can be opened from inside to outside if an emergency occurs. Customization Cooling Solution Air-cooled module solutionApplicable to various medium and small data centers, such as: operator data centers, data centers of various industries (finance, government, energy, medical, etc.) and other enterprise-level data centers. Chilled water module:It is suitable for all kinds of large and medium data centers with chilled water hosts, such as: Internet data centers, operator data centers, data centers in various industries (finance, government, energy, medical, etc.) and other enterprise-level data centers. |
Structure & Components
Rack Multi-functional cabinet developed for large, medium and small data centers. It has the advantages of sturdy structure, strong load-bearing capacity, noble and elegant and assembling structure design. Cabinet integrated three major solutions (power management solution, cable management solution, heat dissipation management solution), It can be used as a modular equipment installation infrastructure, cabinet-type power distribution cabinet, rackmounted battery box, Cabinet integrated user equipment, power distribution, UPS, battery box, and monitoring system, greatly save the equipment area in the computer room. Aisle Containment -Modular design Power Supply- Modular UPS According to the power supply requirements of large and medium-sized data centers, a modular UPS solution has been introduced, which can be flexibly configured with 80-300kVA modular UPS according to the customer's system power supply requirements. The module adopts advanced high-frequency switching technology, fully digital DSP control technology and the world’s leading active PFC and LLC topologies to achieve high input power factor, accurate output current sharing performance, and reliable monitoring and management system. The equipment provides safe, reliable and pure AC power. Cooling System - In Row Air Conditioning Unit Inverter In Row air conditioners are tailor-made high-density cabinets, adopts advanced frequency conversion technology and uses the environmentally friendly refrigerant R410A. The output cooling capacity is adjusted in real time according to the change of the detected load, to avoid frequent start and stop, and to ensure the temperature of the computer room environment. Monitoring System The monitoring system system has the characteristics of simple configuration, strong access, and high reliability. It can manage all power, environment, and cooling in data center, integrate mainstream brand access control, video and other security systems, through distributed collection, high concurrent processing capabilities Meet the needs of networked monitoring and management of multiple computer rooms, allowing data center operation and maintenance personnel to control the operation safety of the computer room in real time. |
Features
Energy saving and high efficiency Efficient power supply and distribution, cooling close to the heat source, effectively reducing the PUE value of the module, isolating cold and hot air flow, eliminating ineffective air circulation and eliminating local hot spots Through integrated management of modules, coordinated operation and improved performance of functional components.
On-demand expansion Standardized, modular and integrated design, saving 30% of construction cost. Cabinet expansion is as simple as building blocks, and computing power grows as needed; Software-defined infrastructure, excellent resource elastic scalability; Meet business elastic scaling requirements and save 40% of initial investment.
Simple operation and maintenance Centralized monitoring of computer room infrastructure, IT infrastructure and cloud platform. Multi-cloud management of physical and virtual resources, Automatic fault location, automatic isolation, efficient operation and maintenance. |
Air Supply Method
Technical Specification
Equipment System | Item | Parameter |
System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets |
1200mm enclosed cold/hot aisle Single-row cabinets | ||
Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | |
Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U |
Protection Class | IP20 | |
Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight |
Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) |
UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | |
Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | |
Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) |
Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | |
Power Supply | 3Phase 380VAC,50Hz | |
Air Supply | Front Supply | |
Type | Enclosed Hot/Cold Aisle | |
Protection | IP20 | |
Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm |
Equipment monitoring | Power supply, battery, power distribution, air conditioning |