Product Details
Place of Origin: China
Brand Name: Coolent
Certification: ISO/CE
Model Number: CYAT41D/U
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: to be Negotiated
Packaging Details: WOODEN
Delivery Time: 4W
Payment Terms: T/T
Supply Ability: 1000/Month
Mounting: |
Floor Standing |
Condition: |
New |
Type: |
Precision Air Conditioning Unit( Air Cooled ) |
Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year |
Name: |
PAC Cooling Unit |
Refrigerant: |
R22(R407C) |
Application: |
Computer Room,Printing Factory/supper Market/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Color: |
Black/Grey White/other Custom Colors |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Mounting: |
Floor Standing |
Condition: |
New |
Type: |
Precision Air Conditioning Unit( Air Cooled ) |
Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year |
Name: |
PAC Cooling Unit |
Refrigerant: |
R22(R407C) |
Application: |
Computer Room,Printing Factory/supper Market/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Color: |
Black/Grey White/other Custom Colors |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Black 41.9KW Precision Air Conditioning Units For Data Center And Computer Room
Product Introduction The purpose of traditional household air conditioners is to make people feel comfortable. It does not provide high cooling capacity and the function of coping with high or low humidity. It cannot adapt to the environment where the electronic equipment is highly concentrated. Precision air handling units are designed for matching production technology, and its accuracy and reliability control can totally meet the requirements of precision electronic equipment environment. The latest CYA series developed by the company can be used in communication rooms in cold regions. The outdoor cold air enters the communication room through the filter to achieve the cooling effect, and the compressor does not run at the same time to save energy. It is an overall unit design with providing high precision, high reliability, high performance, and reliable operation.
Applications
|
Air Supply Method
Technical Features
High reliability Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition. All-day running design can guarantee the main equipment safe operation. All parts had passed severe test and confirmed stable and reliable before delivery.
High energy efficiency Sensible heat ratio is up to 91%. Compressor energy efficiency ratio is over 3.1, and chilled water cooled unit’s cooling energy efficiency is larger than 25. The optimal and high efficiency compressor and fans. “W/M” type evaporator with super large heat exchange area. Independent air duct design can reduce air resistance significantly and minimize fans power. Variable frequency design on ODU is more efficient and has longer working life. Advanced control logic can effectively avoid competitive running and output cooling capacity according to actual cooling capacity demand.
Easy maintenance Front panel maintenance: All maintenance work can be operated from front panel. Air filter with metal frame: Cleanable repeatedly, low maintenance cost Self-cleaning humidifier: lower maintenance work Modular design with least spare parts Pressure difference monitoring for air filters can detect whether air filters was blocked or not.
Multiple types *Wide capacity range: air cooled type(5kW~120kW),Water cooled type(5-120KW),chilled water cooled type(30kW~200kW). *Multiple cooling mode: air cooled, water cooled, glycol cooled, chilled water cooled(with single/dual coil), air cooled & chilled water cooled, air cooled & free cooling, Freon pump free cooling. *Multiple air supplying modes: cap tuyere mode, air duct mode, floorboard mode. *Multiple refrigerant types: R410A, R407C, R22. *Wide ambient air temperature rang: standard range(-20℃~50℃),low temperature range(-40℃~50℃). |
Technical Parameter
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |
Certificates
Factory Details
Packing & Delivery
Case