Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > Precision Air Conditioning Units > PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms

PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYAT50-76

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

Communication Equipment Rooms PAC System

,

80KW Pacu Air Conditioning Unit

,

Precision Air Conditioning Units 50KW

Capacity:
50-80KW
Mounting:
Floor Standing
Condition:
Brand New
Product Type:
Air Cooled Unit/water Cooled Unit/iFree-cooling
Extra Service:
Engineers Available To Service Machinery Overseas
Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year
Name:
PAC Systems(Precision Air Cooling Systems)
Refrigerant:
R22(R407C/R410A)
Product Application:
Computer Room/Printing Factory/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black,Grey, White, Other Colors
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
15500-25500 M3/h
Function:
Cooling Ventilation
Capacity:
50-80KW
Mounting:
Floor Standing
Condition:
Brand New
Product Type:
Air Cooled Unit/water Cooled Unit/iFree-cooling
Extra Service:
Engineers Available To Service Machinery Overseas
Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year
Name:
PAC Systems(Precision Air Cooling Systems)
Refrigerant:
R22(R407C/R410A)
Product Application:
Computer Room/Printing Factory/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black,Grey, White, Other Colors
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
15500-25500 M3/h
Function:
Cooling Ventilation
PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms

PAC System With 50-80KW Applied In Server Rooms, Communication Equipment Rooms

 

Products Introduction                           

Compared with ordinary air conditioners, Coolnet's precision air conditioners have high-precision, sensitive, microprocessor-based intelligent control systems, which can quickly respond to changes in the external environment, thereby ensuring that environmental changes are maintained in a stable environment. Within the setting range. For example, human-computer interaction interface, alarm protection, network monitoring and other functions. As a result, Coolnet CyberMaster PAC can be the best choices for server rooms, communication equipment rooms to provide constant humidity, cleaniless and temperature.

 

Benefits                                                  

PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms 0

PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms 1

 

Applications                                          

PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms 2
  • IDC, Computer room
  • Network equipment room, Server room,communication equipment room
  • Monitoring room, Power distribution room and battery room
  • High precision lab, Test room, Inspection room, Measuring room
  • Industrial control room, High precision workshop
  • Archive, Storage room, Museum, Wine cellar

 

Technical Features                                      

 

High reliability

Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition.

All-day running design can guarantee the main equipment safe operation.

All parts had passed severe test and confirmed stable and reliable before delivery.

 

High energy efficiency

Sensible heat ratio is up to 91%.

Compressor energy efficiency ratio is over 3.1, and chilled water cooled unit’s cooling energy efficiency is larger than 25.

The optimal and high efficiency compressor and fans.

“W/M” type evaporator with super large heat exchange area.

Independent air duct design can reduce air resistance significantly and minimize fans power.

Variable frequency design on ODU is more efficient and has longer working life.

Advanced control logic can effectively avoid competitive running and output cooling capacity according to actual cooling capacity demand.

 

Easy maintenance

Front panel maintenance: All maintenance work can be operated from front panel.

Air filter with metal frame: Cleanable repeatedly, low maintenance cost

Self-cleaning humidifier: lower maintenance work

Modular design with least spare parts

Pressure difference monitoring for air filters can detect whether air filters was blocked or not.

PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms 3

 

 

Main Parts                                 

PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms 4

Compressor

  • Apply the scroll compressor (SCROLL) produced by Copeland with high energy efficiency ratio;
  • The reduction of the moving parts of the scroll compressor greatly reduces the noise and vibration of the unit;
  • The rotation angle of the compressor discharge process exceeds 540 degrees;

 

Evaporator

  • Equipped with a special dehumidification solenoid valve. When dehumidifying, only one side of the double-sided evaporator is used.
  • The solenoid valve ensures that only 2/3 of its area is used for dehumidification, achieving a fast and energy-saving dehumidification effect, avoiding excessive dehumidification and increasing reheating.
  • Design to achieve energy saving purposes.

 

Humidifier

  • The unique detachable electrode humidifier is located in the lower part of the unit and the compressor is in an independent space, which is isolated from the airflow and can be maintained without stopping.
  • Removable filter core, electrode and tank can be cleaned, even non-professionals can do it.
  • There are no special requirements for water quality, and no prior pretreatment is required.

 

EC Fan

  • Electronic commutation centrifugal fan, automatic adjustment of the fan system;
  • Adopt brushless DC motor, built-in circuit, and stepless speed regulation according to indoor temperature.
  • Low starting current, lower than running current (ordinary AC motor, starting current is 3.5 times the running current)

 

Technical Parameters                                       

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

Certificates                                    

PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms 5

 

Factory Details                                           

PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms 6

 

Packing & Delivery                                       

PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms 7

 

Case                                     

PAC System 50-80KW Applied In Server Rooms Communication Equipment Rooms 8