Large Exchange Room And Communication Room PAC For IT And Financial Industry

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYA T70,T76, T85,T90,T100

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

Standing Precision Air Conditioners

,

Financial Industry Precision Air Conditioners

Name:
Precision Air Conditioners (PAC)
Type:
Air Cooled Unit/Water Cooled Unit/Glycol Cold Unit
Capacity:
70-102kW
Product Voltage:
380v/220v,220V/380V,380V/415V
Refrigerant:
R22(R407C/R410A)
Airflow:
18500-25000 M3/h
Mounting:
Standing
Color:
Black/Grey /White/Other Colors
Application:
Computer Room,Data Center, Large Supermarket
Product Function:
Precision Air Conditioning
Warranty:
1 Year
Extra Service Provided:
Engineers Available To Service Machinery Overseas
Name:
Precision Air Conditioners (PAC)
Type:
Air Cooled Unit/Water Cooled Unit/Glycol Cold Unit
Capacity:
70-102kW
Product Voltage:
380v/220v,220V/380V,380V/415V
Refrigerant:
R22(R407C/R410A)
Airflow:
18500-25000 M3/h
Mounting:
Standing
Color:
Black/Grey /White/Other Colors
Application:
Computer Room,Data Center, Large Supermarket
Product Function:
Precision Air Conditioning
Warranty:
1 Year
Extra Service Provided:
Engineers Available To Service Machinery Overseas
Large Exchange Room And Communication Room PAC For IT And Financial Industry

Large Exchange Room And Communication Room PAC For IT And Financial Industry

 

Product Introduction                                            

The precision air conditioner for the computer room is a special air conditioner designed for the computer room of modern electronic equipment. It has a higher accuracy and reliability during working than ordinary air conditioners. To ensure the stability and reliability of the equipment in the computer room, the temperature and humidity of the computer room environment must be strictly controlled within a specific range. The CyberMaster series can control the temperature and humidity of the computer room at a difference of 1 degree, which greatly improves the life and reliability of the equipment.Therefore, it can be the best choice for large exchange room and communication room.

 

Benefits                                                

Large Exchange Room And Communication Room PAC For IT And Financial Industry 0

Large Exchange Room And Communication Room PAC For IT And Financial Industry 1

Application Range                                

Large Exchange Room And Communication Room PAC For IT And Financial Industry 2
  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

 

Main Components                                                     

 

Expansion Valve

We use famous brands such as Emerson and Danfoss which has excellent product performance, high sensitivity and easy replacement.

 

Humidifier

Electrode humidifier, using tap water, with automatic cleaning function, can quickly generate pure steam, maintenance does not stop.

 

Scroll Compressor

International famous brand compressor, COP value greater than 4.0, equipped with safety devices to ensure high efficiency, low noise and long life of the unit.

 

Indoor Blower Fan

Direct-drive centrifugal fan with backward curved blades has an average life span of 10 years and can achieve continuous operation for 365 days * 24 hours;

Energy-saving EC fan, DC drive, is better than traditional fans in the field of energy saving.

Large Exchange Room And Communication Room PAC For IT And Financial Industry 3

 

Technical Features                                        

Large Exchange Room And Communication Room PAC For IT And Financial Industry 4

 

High reliability

Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition.

All-day running design can guarantee the main equipment safe operation.

 

High energy efficiency

Sensible heat ratio is up to 91%.

Compressor energy efficiency ratio is over 3.1, and chilled water

cooled unit’s cooling energy efficiency is larger than 25.

The optimal and high efficiency compressor and fans.

“W/M” type evaporator with super large heat exchange area.

Independent air duct design can reduce air resistance significantly and minimize fans power.

Variable frequency design on ODU is more efficient and has longer working life.

 

Easy maintenance

Front panel maintenance: All maintenance work can be operated from front panel.

Air filter with metal frame: Cleanable repeatedly, low maintenance cost

Self-cleaning humidifier: lower maintenance work

Modular design with least spare parts

Pressure difference monitoring for air filters can detect whether air filters was blocked or not.

 

Multiple types

Wide capacity range:air cooled type(5kW~120kW),Water cooled type(5-120KW),chilled water cooled type(30kW~200kW).

Multiple cooling mode:air cooled, water cooled, glycol cooled, chilled water cooled(with single/dual coil), air cooled & chilled water cooled, air cooled & free cooling, Freon pump free cooling.

Multiple air supplying modes:cap tuyere mode, air duct mode, floorboard mode.

Multiple refrigerant types: R410A, R407C, R22.

Wide ambient air temperature rang:standard range(-20℃~50℃),low temperature range(-40℃~50℃).

 

Technical Parameters                                     

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 

Certificates                                      

Large Exchange Room And Communication Room PAC For IT And Financial Industry 5

 

Factory Details                                         

Large Exchange Room And Communication Room PAC For IT And Financial Industry 6

 

Packing & Delivery                                       

Large Exchange Room And Communication Room PAC For IT And Financial Industry 7

 

Case                                         

Large Exchange Room And Communication Room PAC For IT And Financial Industry 8