Cooling Capacity: |
50-120KW |
Mounting: |
Floor Standing |
Product Type: |
Precision Air Conditioning( Air Cooled ) |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year(12months) |
Name: |
Close Control Precision Air Conditioning Unit |
Refrigerant: |
R22(R407C/R410A) |
Application: |
Computer Room/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
Down Flow/Front Flow |
Voltage: |
380v/220v,220V/380V,380V/415V |
Cooling Capacity: |
50-120KW |
Mounting: |
Floor Standing |
Product Type: |
Precision Air Conditioning( Air Cooled ) |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year(12months) |
Name: |
Close Control Precision Air Conditioning Unit |
Refrigerant: |
R22(R407C/R410A) |
Application: |
Computer Room/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
Down Flow/Front Flow |
Voltage: |
380v/220v,220V/380V,380V/415V |
Frequency Conversion Precision Air Conditioning Units Used In UPS And Battery Rooms
Product Introduction With the improvement of electrical equipment integration degree, equipment unit volume power density increase, also more and more strict control of the indoor temperature, room temperature control equipment to ensure good indoor environment is becoming more and more important to the equipment room dedicated brand cooling air conditioning units,24"365 full-year refrigeration,effectively reduce the indoor temperature, and can consider introducing outdoor air to replace the wind, reduce the refrigeration system on time, according to the setting of indoor temperature and outdoor natural temperature difference between air section.
Benefits |
Technical Features
1. High quality control component. 2. Efficient evaporator made from advanced technology and with larger heat exchange area. 3. Danfoss brand quality expansion valve. 4. Internationally advanced electrode steam humidification system. 5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment. 6. G4 level air filter to guarantee the server room air purity. 7. Copeland hermetic scroll compressor. 8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional. 9. Highly efficient PTC electrical heater. 10. Anti-corrosion alloy condenser. |
Applications
|
|
Main Components
Expansion Valve We use famous brands such as Emerson and Danfoss which has excellent product performance, high sensitivity and easy replacement.
Humidifier Electrode humidifier, using tap water, with automatic cleaning function, can quickly generate pure steam, maintenance does not stop.
Scroll Compressor International famous brand compressor, COP value greater than 4.0, equipped with safety devices to ensure high efficiency, low noise and long life of the unit.
Indoor Blower Fan Direct-drive centrifugal fan with backward curved blades has an average life span of 10 years and can achieve continuous operation for 365 days * 24 hours; Energy-saving EC fan, DC drive, is better than traditional fans in the field of energy saving. |
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |