products
products
Home > products > Precision Air Conditioning Units > 75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYAT76-90

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

75KW Precision Air Conditioning Units

,

75KW Capacity Air Cooling Units

,

Black Precision Ac For Data Center

Cooling:
75-90KW
Product Mounting:
Floor Standing
Condition:
Full New
Type:
Precision Air Conditioning Unit( Air Cooled )
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12month)
Product Name:
Precision Air Conditioning Units
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room/Printing Factory/Office/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black/Grey/White/Other Custom Colors
Airflow:
Down Flow/Front Flow
Cooling:
75-90KW
Product Mounting:
Floor Standing
Condition:
Full New
Type:
Precision Air Conditioning Unit( Air Cooled )
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12month)
Product Name:
Precision Air Conditioning Units
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room/Printing Factory/Office/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black/Grey/White/Other Custom Colors
Airflow:
Down Flow/Front Flow
75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers

 

Product Introduction                               

Coolnet server air conditioners series can be used in precision environmental adjustments in big, small and medium computer rooms, battery rooms, equipment rooms and other places. The unit adopts advanced design concepts with strictly tested by precision air-conditioning professional laboratories. It has high efficiency, energy saving, stability and long life. It has operating characteristics, and has constant temperature and humidity adjustment functions, which can meet the precise environmental adjustment needs of different industries such as IT, electric power, finance, medical laboratories and transportation.

 

Benefits                                                      

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers 0

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers 1

 

Applications                                       

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers 2
  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

 

Technical Features                                

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers 3

 

High sensible heat
The host and peripherals, servers, switches, optical transceivers and other computer equipment installed in the computer room, as well as power support equipment, such as UPS power supply, will dissipate heat into the computer room by means of heat transfer, convection, and radiation. These heat only cause the temperature in the computer room. The increase is sensible heat. The heat dissipation of a server cabinet ranges from a few kilowatts to a dozen kilowatts per hour. If a blade server is installed, the heat dissipation will be higher. The heat dissipation of large and medium-sized computer room equipment is about 400W/m2, and the data center with higher installed density may reach more than 600W/m2. The sensible heat ratio in the computer room can be as high as 95%.

 

Low latent heat
It does not change the temperature in the computer room, but only changes the moisture content of the air in the computer room. This part of the heat is called latent heat. There is no humidity dissipation device in the computer room, and the latent heat mainly comes from the staff and the outdoor air, while the large and medium-sized computer room generally adopts the management mode of man-machine separation. Therefore, the latent heat in the engine room is small.

 

Uninterrupted operation, year-round cooling
The heat dissipation of the equipment in the computer room is a steady heat source and operates uninterrupted throughout the year. This requires a set of uninterrupted air conditioning guarantee system, and there are also high requirements on the power supply of the air conditioning equipment. And for the air-conditioning system that protects important computer equipment, there should also be a generator set as a backup power supply. The long-term steady-state heat source causes the need for cooling even in winter, especially in the southern region. In the northern region, if cooling is still required in winter, the condensing pressure of the unit and other related issues need to be considered when selecting an air-conditioning unit. In addition, the proportion of outdoor cold air intake can be increased to achieve the purpose of energy saving.

 

Technical Parameters                                 

 

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 

Certificates                                        

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers 4

 

Factory Details                                   

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers 5

 

Packing & Delivery                                            

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers 6

 

Case                                              

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers 7