13000 - 18500m3/H Precision Air Handling Units For Server Rooms

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYAT40D/U

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

18500m3/H Precision Air Handling Units

,

Server Rooms Precision AHU

,

70KW Precision Air Handling Units

Cooling Capacity:
45-70KW
Mounting:
Standing
Condition:
Brand New
Type:
Precision Air Conditioning Units( Air Cooled/chilled Water)
Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12 Month)
Product Name:
Precision Air Conditioning System
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory/cinema/Restaurant/Office/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black/Grey
Airflow:
Down Flow/Front Flow
Cooling Capacity:
45-70KW
Mounting:
Standing
Condition:
Brand New
Type:
Precision Air Conditioning Units( Air Cooled/chilled Water)
Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12 Month)
Product Name:
Precision Air Conditioning System
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory/cinema/Restaurant/Office/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Black/Grey
Airflow:
Down Flow/Front Flow
13000 - 18500m3/H Precision Air Handling Units For Server Rooms

Airflow 13000-18500m3/H Precision Air Handling Units For High-Tech Labs And Server Rooms

 

Product Introduction                                       

If the environment of the data room is not suitable, it will have a negative impact on the data processing and storage work, which may cause data operation errors, downtime, and even cause frequent system failures and complete shutdowns. Therefore, choosing high-quality, high-efficiency, and well-branded computer room precision air conditioners to ensure the environment and temperature and humidity of the computer room is an essential part for companies and enterprises that own a data computer room. CyberMasterTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMasterTM meets the cooling demand and reduce the PUE of the data center.

 

Feature and Benefits                                         

13000 - 18500m3/H Precision Air Handling Units For Server Rooms 0

13000 - 18500m3/H Precision Air Handling Units For Server Rooms 1

Air Supply Method                                    

13000 - 18500m3/H Precision Air Handling Units For Server Rooms 2

Main Parts                                     

13000 - 18500m3/H Precision Air Handling Units For Server Rooms 3

Fan:

Use the efficient and low-noise EBM backward tilt centrifugal wind motorized balance test to ensure long life, high energy efficiency, low energy consumption and low noise operation. Compared with equipment with the same air volume in the industry, the power consumption is the lowest.

 

Condenser:

The air-cooled condenser is made of marine grade corrosion-resistant materials, has outstanding rigidity and anti-corrosion functions, and is accustomed to various environmental conditions. Fully adjustable speed electric fans are used to achieve energy saving and low noise.

 

Compressor:

Use a scroll compressor with a high energy efficiency ratio. The reduction of the moving parts of the scroll compressor reduces the noise and sensation of the unit a lot; the compression process of the compressor is continuous and stable; the rotation viewpoint of the exhaust process of the compressor exceeds 540 degrees; there is no heat exchange during the inhalation and compression process; In the process of compaction, the direction of refrigerant airflow is not changed; the airflow loss is reduced; the scroll compressor does not need high and low pressure valves; the volume loss of the valve is reduced, and the patented dynamic and static scroll separation technology can effectively avoid liquid shock; launch The current is low. The energy efficiency ratio of similar compressors is the highest, reaching 3.4.

 

Expansion Valve:

Smoothly adjust the throttle opening and cooperate with the variable capacity compressor to achieve energy saving;Wide adjustment range, reduce superheat and improve energy efficiency ratio;Reduce cooling capacity and load;Fast response speed, realizing precise refrigeration
Dual electronic expansion valve design, low load dehumidification

 

Humidifier:

Direct electrode humidifier;W-type electrode combination suitable for poor water quality;Fuzzy logic control humidification program
Removable for cleaning;Microcomputer-controlled automatic flushing cycle process;Low noise water supply solenoid valve to ensure quietness

 

 

Applications                                               

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
13000 - 18500m3/H Precision Air Handling Units For Server Rooms 4

 

Technical Parameters                                             

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 