Cooling Capacity: |
45-50kw |
Product Condition: |
New |
Mounting: |
Floor Standing Mount |
Type Of Product: |
Precision Air Conditioning Unit(chilled Water) 3ton 5ton 10ton |
After-sales Service: |
Engineers Available To Service Machinery Overseas |
Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year(12 Month) |
Product Name: |
Precision Air Conditioning |
Precision Air Conditioning: |
R22(R407C/R410A) |
Application: |
Computer Room/Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Color: |
Black/Grey/White/other Custom Colors |
Type Of Fan: |
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
8000~50000 M3/h |
Cooling Capacity: |
45-50kw |
Product Condition: |
New |
Mounting: |
Floor Standing Mount |
Type Of Product: |
Precision Air Conditioning Unit(chilled Water) 3ton 5ton 10ton |
After-sales Service: |
Engineers Available To Service Machinery Overseas |
Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year(12 Month) |
Product Name: |
Precision Air Conditioning |
Precision Air Conditioning: |
R22(R407C/R410A) |
Application: |
Computer Room/Printing Factory/cinema/supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Color: |
Black/Grey/White/other Custom Colors |
Type Of Fan: |
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
8000~50000 M3/h |
Low Energy Demand 10000m3/H Airflow Air Cooling For Program-Controlled Switch Rooms
Product Introduction Precision air conditioners are widely used in high-precision environments such as computer rooms, program-controlled switch rooms, satellite mobile communication stations, large medical equipment rooms, laboratories, testing rooms, and precision electronic instrument production workshops. Various indicators such as cleanliness and airflow distribution have high requirements. The computer room air conditioner operates 24 hours a day, 365 days a year. It can ensure the normal refrigeration cycle of the computer room through the controllable outdoor condenser, thereby ensuring the normal operation of the equipment in the computer room.
Benefits |
![]() |
Technical Features
![]() |
1. High quality control component. 2. Efficient evaporator made from advanced technology and with larger heat exchange area. 3. Danfoss brand quality expansion valve. 4. Internationally advanced electrode steam humidification system. 5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment. 6. G4 level air filter to guarantee the server room air purity. 7. Copeland hermetic scroll compressor. 8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional. 9. Highly efficient PTC electrical heater. 10. Anti-corrosion alloy condenser. |
Applications
|
![]() |
Advantages
![]() |
Precise and reliable
Energy saving and high efficiency
Multiple air supply
Static pressure box air supply |
Technical Parameters
Model: CYA | S20D/U | S23D/U | S26D/U | S28D/U | S31D/U | S35D/U | S40D/U | S45D/U | |
Power Supply | 380V 3Ph-50HZ | ||||||||
Air Discharge | Upflow/Downflow | ||||||||
Cooling Capacity :24℃/50%RH | |||||||||
Total Capacity | KW | 20.5 | 23.5 | 26.8 | 28.3 | 31.5 | 35.5 | 40.2 | 45.6 |
Sensible | KW | 18.9 | 21.6 | 24.2 | 26.1 | 28.9 | 33.2 | 37.6 | 42.2 |
AEER | w/w | 3.7 | 3.6 | 3.6 | 3.7 | 3.7 | 3.7 | 3.7 | 3.6 |
Air Flow | m3/h | 6830 | 7650 | 7580 | 8500 | 9200 | 9800 | 10600 | 12000 |
Compressor Hermetic scroll | |||||||||
Refrigerant | R407C | ||||||||
Compressor quantity | PC | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Fan Section Centrifugal fan (Optional EC) | |||||||||
Fan quantity | PC | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 |
Rated current | A | 2.5 | 2.5 | 2.8 | 3.2 | 3.5 | 4.1 | 4.4 | 4.9 |
Rated power | W | 1050 | 1100 | 1200 | 1300 | 1320 | 2000 | 2150 | 2400 |
Reheat Capacity | KW | 6 | 6 | 6 | 6 | 9 | 9 | 9 | 9 |
Reheat Material | PTC | ||||||||
Humidifier Section Electrode type | |||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 15 |
Condensor Model | 58 | 58 | 80 | 80 | 100 | 120 | 150 | 150 |
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |