Product Details
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE,ISO
Model Number: MDC
Payment & Shipping Terms
Minimum Order Quantity: 1set
Price: 1800-30000USD
Packaging Details: Packed in plywooden case, standard export package
Delivery Time: 10-25 working days
Payment Terms: T/T, L/C
Supply Ability: 300 PCS PER MONTG
Cooling Capacity: |
20-50KW |
Condition: |
Brand New |
Mounting: |
Floor Standing |
Type: |
Modular Data Centers With 19" Standard Server Cabinet |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year(12 Month With No Artificial Damage) |
Product Name: |
Modular Data Center |
Refrigerant: |
R22(R407C/R410A) |
Application: |
5G/Smart City/Edge Computing/IDC/Large Enterprises/Government/Universities |
Color: |
Black/Grey |
Fan Type: |
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan |
Power Input: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
2000~50000 M3/h |
Cooling Capacity: |
20-50KW |
Condition: |
Brand New |
Mounting: |
Floor Standing |
Type: |
Modular Data Centers With 19" Standard Server Cabinet |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year(12 Month With No Artificial Damage) |
Product Name: |
Modular Data Center |
Refrigerant: |
R22(R407C/R410A) |
Application: |
5G/Smart City/Edge Computing/IDC/Large Enterprises/Government/Universities |
Color: |
Black/Grey |
Fan Type: |
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan |
Power Input: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
2000~50000 M3/h |
Modular Data Center With All-In-One UPS And Cooling System High Density For Smart City
Product Introduction As a carrier of massive data, data centers still face many problems such as high energy consumption, high cost, and low resource utilization. Therefore, modular data centers and containerized micro-module data centers have become the design trends of the new generation of data centers. The Coolnet mini modular data center can flexibly adopt the layout of double-row cabinets + hot and cold aisles or single-row cabinets + cold and hot aisles according to user site conditions. Modular data centers are designed to cope with server changes such as cloud computing, virtualization, centralization, and high density, improve data center operation efficiency, reduce energy consumption, and achieve rapid capacity expansion without affecting each other.
Benefits
|
Features
Intelligent Intelligent fire control can be implemented for every top plate. Once fire signal alarm in room, the top plate will open automatically,and fire extinguishing gases can enter the aisle.
Convinence No threshold design,convinent for wheelbarrow.
Aesthetic The window is made of prespective tempering glass with high mechanical strenth,good permeability.The Black coating of cold rolled steel plate borders and cabinet style is consistent and also coorinated with the computer room.
Automatical door structure The sliding door can be closed automatically,can be installed door access system and can be opened from inside to outside if an emergency occurs. |
Main Basic Unit Introduction
Power Supply- Modular UPS Aisle Containment Good sealing Good light transmission |
Technical Specification
Equipment System | Item | Parameter |
System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets |
1200mm enclosed cold/hot aisle Single-row cabinets | ||
Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | |
Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U |
Protection Class | IP20 | |
Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight |
Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) |
UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | |
Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | |
Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) |
Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | |
Power Supply | 3Phase 380VAC,50Hz | |
Air Supply | Front Supply | |
Type | Enclosed Hot/Cold Aisle | |
Protection | IP20 | |
Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm |
Equipment monitoring | Power supply, battery, power distribution, air conditioning |
Certificates
Factory Details
Parking & Delivery
Cases