Home > products > Precision Air Conditioning Units > Server Rooms Precision Air Handling Units With EC Fan And Large Airflow

Server Rooms Precision Air Handling Units With EC Fan And Large Airflow

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYA T90 T95 T100

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

Server Rooms Precision Air Handling Units

,

EC Fan Precision Air Handling Units

,

Large Airflow Precision Air Handling Units

Cooling Capacity:
65-100KW
Mounting:
Floor Standing Units
Condition:
Brand New
Type Of Power Supply:
Air Cooled Unit/Chilled Water Unit/Water Cooled Unit/Glycol Cold Unit
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12 Month With No Artificial Damage)
Name:
Precision Air Conditioning Units
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Data Center, Libraries, Laboratories,Large Supermarket
Color:
Black/Grey/Blue/Other Custom Colors
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
5000~30000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Cooling Capacity:
65-100KW
Mounting:
Floor Standing Units
Condition:
Brand New
Type Of Power Supply:
Air Cooled Unit/Chilled Water Unit/Water Cooled Unit/Glycol Cold Unit
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year(12 Month With No Artificial Damage)
Name:
Precision Air Conditioning Units
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Data Center, Libraries, Laboratories,Large Supermarket
Color:
Black/Grey/Blue/Other Custom Colors
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
5000~30000 M3/h
Voltage:
380v/220v,220V/380V,380V/415V
Server Rooms Precision Air Handling Units With EC Fan And Large Airflow

Precision Air Handling Units For Server Rooms With EC Fan And Large Airflow

 

Product Introduction                                         

Precision air conditioner refers to a special air conditioner that can meet the operating conditions of the computer room, or can provide a constant temperature and humidity environment for the equipment. Under normal circumstances, in the computer room and the environment with many precision instruments and equipment, if the temperature and humidity are not properly controlled, it will increase the loss of the enterprise and shorten the service life of the equipment.

 

Feature and Benefits                                       

Server Rooms Precision Air Handling Units With EC Fan And Large Airflow 0

Server Rooms Precision Air Handling Units With EC Fan And Large Airflow 1

 

 

Applications                                                

Server Rooms Precision Air Handling Units With EC Fan And Large Airflow 2
  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

 

Main Parts                                             

 

DC inverter compressor
U
sing R410A environmentally friendly refrigerant, DC frequency conversion, high efficiency and energy saving;
Dynamic cooling to adapt to the rapidly changing heat load of the computer room;
Brushless DC maintenance-free motor, easy to operate and maintain;

 

EC fan
The use of electronically commutated synchronous EC electrodes can save energy by 20% to 30%;
Automatically adjust the fan speed according to cooling demand or wind pressure, and provide air volume on demand;
Soft start function, low starting current;

 

Dual electronic expansion valve design
Wide adjustment range, reduce superheat and improve energy efficiency ratio;
Accurate matching of cooling capacity and load;Fast response speed to achieve precise cooling;

Server Rooms Precision Air Handling Units With EC Fan And Large Airflow 3

 

 

Advantages                                           

Server Rooms Precision Air Handling Units With EC Fan And Large Airflow 4

Intelligent control
Fightly intelligent microprocessor control system, reliable operation, convenient use and maintenance, strong anti-interference ability, can keep the unit in the best operating state;
With various protection functions, it can also realize unit joint control, and can be connected to a common open protocol to easily realize building control (support RS485,RS232, ModBUS, LonWORKS, BacNET and lP protocol SNMP)

Health and Environmental Protection
Effective ventilation, providing fresh and clean natural air,reducing indoor pollutants and improving indoor air quality.
The unit uses environmentally friendly refrigerant R4O7C/R4104, which is most conducive to ecological environment protection, and pay attention to environmental sustainable development.

 

Technical Parameters                                      

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180
 

Certificates                                        

Server Rooms Precision Air Handling Units With EC Fan And Large Airflow 5

 

Factory Details                                                

Server Rooms Precision Air Handling Units With EC Fan And Large Airflow 6

 

Packing and Delivery                                            

Server Rooms Precision Air Handling Units With EC Fan And Large Airflow 7

 

Case                                                 

Server Rooms Precision Air Handling Units With EC Fan And Large Airflow 8