Product Details
Place of Origin: China
Brand Name: Coolent
Certification: ISO/CE
Model Number: CYA S35D/U S40D/U S45D/U
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: to be Negotiated
Packaging Details: WOODEN
Delivery Time: 4W
Payment Terms: T/T
Supply Ability: 1000/Month
Cooling Capacity: |
35-80KW |
Mounting: |
On Floor Standing Type |
Product Condition: |
Brand New |
Type: |
Air Cooled Unit/Chilled Water Cooled/Water Cooled Unit/Glycol Cold Unit |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year(12 Month) |
Name: |
Precision Air Conditioners (PAC) |
Refrigerant: |
R22(R407C/R410A) |
Application: |
Computer Room/Printing Factory/Cinema/Supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Color: |
Black/Grey/Blue/Other Colors |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
2000~40000 M3/h |
Voltage: |
380v/220v,220V/380V,380V/415V |
Cooling Capacity: |
35-80KW |
Mounting: |
On Floor Standing Type |
Product Condition: |
Brand New |
Type: |
Air Cooled Unit/Chilled Water Cooled/Water Cooled Unit/Glycol Cold Unit |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Operating Voltage: |
380/400 VAC,230 VAC,220V |
Warranty: |
1 Year(12 Month) |
Name: |
Precision Air Conditioners (PAC) |
Refrigerant: |
R22(R407C/R410A) |
Application: |
Computer Room/Printing Factory/Cinema/Supper Marekt/restaurant/Offfice/Kindergarten,Industrial,Heat Recovery,adjust Cold/heat/humidity |
Color: |
Black/Grey/Blue/Other Colors |
Power: |
3N-380V-50Hz,220v/50hz/60hz |
Airflow: |
2000~40000 M3/h |
Voltage: |
380v/220v,220V/380V,380V/415V |
Hermetic Compressor Computer Room Air Cooling Unit For Large Switch Stations
Products Introduction Computer room air conditioner, also known as constant temperature and humidity air conditioner, refers to a special precision air conditioner that can fully meet the environmental conditions of the computer room. Precision air conditioners can completely provide a stable and safe operation for eqipment through precise control of environmental temperature, humidity and other factors, reduce the operating cost of enterprises, and provide a stable and safe operating environment for electronic equipment in the data center.
Applications
|
Main Components
Expansion Valve We use famous brands such as Emerson and Danfoss which has excellent product performance, high sensitivity and easy replacement.
Humidifier Electrode humidifier, using tap water, with automatic cleaning function, can quickly generate pure steam, maintenance does not stop.
Scroll Compressor International famous brand compressor, COP value greater than 4.0, equipped with safety devices to ensure high efficiency, low noise and long life of the unit.
Indoor Blower Fan Direct-drive centrifugal fan with backward curved blades has an average life span of 10 years and can achieve continuous operation for 365 days * 24 hours; Energy-saving EC fan, DC drive, is better than traditional fans in the field of energy saving. |
Technical Features
1) Large air volume and small enthalpy difference. In the case of a certain cooling capacity, the increase of the air volume will reduce the enthalpy difference, so the general unit can only operate under the condition that the sensible heat ratio is appropriately high, which is just in line with the load characteristics of the machine room.
2) The heat load of the machine room changes greatly. The precise air conditioning system of the computer room must be able to adapt to the change of this load, so that the electronic components can work in the required environmental conditions and ensure the reliability of the circuit function.
3) Reliability. For the requirements of high reliability of the computer room precision air conditioning system, it is necessary to take a series of measures in the design and production of the structure and control system, as well as the composition of the air conditioning system, for the special precision air conditioner for the computer room. |
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |