High Efficiency Electrode Humidifier Precise Server Room AC Units Dedicated

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYA T60 T70 T75

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

Server Room Precision Air Conditioner

,

Dedicated Precision Air Conditioner

,

Precise Server Room AC Units

Cooling Capacity:
60-70KW
Mounting:
Floor Standing Type
Condition:
Brand New
Type:
Precision Air Conditioning Unit( Air Cooled/Water Cooled/Chilled Water/Dual Cooling Systems )
Operating Voltage:
380/400 VAC, 230 VAC, 220V
Warranty:
1 Year(12 Month)
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory, Office,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Blue/Black/Grey/other Custom Colors
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
Down Ward Flow
Cooling Capacity:
60-70KW
Mounting:
Floor Standing Type
Condition:
Brand New
Type:
Precision Air Conditioning Unit( Air Cooled/Water Cooled/Chilled Water/Dual Cooling Systems )
Operating Voltage:
380/400 VAC, 230 VAC, 220V
Warranty:
1 Year(12 Month)
Refrigerant:
R22(R407C/R410A)
Application:
Computer Room,Printing Factory, Office,Industrial,Heat Recovery,adjust Cold/heat/humidity
Color:
Blue/Black/Grey/other Custom Colors
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
Down Ward Flow
High Efficiency Electrode Humidifier Precise Server Room AC Units Dedicated

High Efficiency Electrode Humidifier Precise Server Rooms Dedicated Air Conditioners

 

 

Products Introduction                                         

Coolnet computer room precision air conditioner has the functions of fresh air energy saving, large air volume, high sensible heat, high efficiency filtration, network monitoring and management, fault SMS prompt, automatic recovery of incoming calls, etc., to meet the heat dissipation requirements of high load and long-term continuous operation of the computer room. Therefore, precision air conditioners are now widely used.

 

Benefits                                            

High Efficiency Electrode Humidifier Precise Server Room AC Units Dedicated 0

High Efficiency Electrode Humidifier Precise Server Room AC Units Dedicated 1

Scope of Applications                                        

High Efficiency Electrode Humidifier Precise Server Room AC Units Dedicated 2
  • IDC, Computer room
  • Network equipment room, Server room,communication equipment room
  • Monitoring room, Power distribution room and battery room
  • High precision lab, Test room, Inspection room, Measuring room
  • Industrial control room, High precision workshop
  • Archive, Storage room, Museum, Wine cellar

Main Parts                                             

 

Compressor

  • Apply the scroll compressor (SCROLL) produced by Copeland with high energy efficiency ratio;
  • The reduction of the moving parts of the scroll compressor greatly reduces the noise and vibration of the unit;
  • The rotation angle of the compressor discharge process exceeds 540 degrees;

 

Evaporator

  • Equipped with a special dehumidification solenoid valve. When dehumidifying, only one side of the double-sided evaporator is used.
  • The solenoid valve ensures that only 2/3 of its area is used for dehumidification, achieving a fast and energy-saving dehumidification effect, avoiding excessive dehumidification and increasing reheating.
  • Design to achieve energy saving purposes.

 

Humidifier

  • The unique detachable electrode humidifier is located in the lower part of the unit and the compressor is in an independent space, which is isolated from the airflow and can be maintained without stopping.
  • Removable filter core, electrode and tank can be cleaned, even non-professionals can do it.
  • There are no special requirements for water quality, and no prior pretreatment is required.

 

EC Fan

  • Electronic commutation centrifugal fan, automatic adjustment of the fan system;
  • Adopt brushless DC motor, built-in circuit, and stepless speed regulation according to indoor temperature.
  • Low starting current, lower than running current (ordinary AC motor, starting current is 3.5 times the running current)
High Efficiency Electrode Humidifier Precise Server Room AC Units Dedicated 3

 

Technical Features                                         

High Efficiency Electrode Humidifier Precise Server Room AC Units Dedicated 4

High reliability

  • Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition.
  • All-day running design can guarantee the main equipment safe operation.
  • All parts had passed severe test and confirmed stable and reliable before delivery.

High energy efficiency

  • Sensible heat ratio is up to 91%.
  • Compressor energy efficiency ratio is over 3.1, and chilled water
  • cooled unit’s cooling energy efficiency is larger than 25.

Easy maintenance

  • Front panel maintenance: All maintenance work can be operated from front panel.
  • Air filter with metal frame: Cleanable repeatedly, low maintenance cost
  • Self-cleaning humidifier: lower maintenance work

Multiple types

  • Wide capacity range:air cooled type(5kW~120kW),Water cooled type(5-120KW),chilled water cooled type(30kW~200kW).
  • Multiple cooling mode:air cooled, water cooled, glycol cooled, chilled water cooled(with single/dual coil), air cooled & chilled water cooled, air cooled & free cooling, Freon pump free cooling.

Technical Parameters                                                         

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model   2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

 

Certificates                                                           

High Efficiency Electrode Humidifier Precise Server Room AC Units Dedicated 5

 