Send Message
Hefei Coolnet power Co., ltd
products
products
Home > products > Hot Cold Aisle Containment > Cold Aisle Micro Modular Data Center With Modular UPS And In Row AC Units

Cold Aisle Micro Modular Data Center With Modular UPS And In Row AC Units

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ROHS,ISO

Model Number: IMDC

Payment & Shipping Terms

Minimum Order Quantity: 1 set

Price: 8000-30000USD per set

Packaging Details: Packed in plywooden case and CTN

Delivery Time: 15-20days

Payment Terms: L/C, T/T

Supply Ability: 200 sets per month

Get Best Price
Highlight:

Inrow AC Units Micro Data Center

,

Inrow AC Units Modular Data Center

,

Cold Aisle Micro Data Center

Name:
Data Center Rack Cold Aisle Containment
Material:
2.0mm Cold Rolled Steel
Hot Air Containment:
Included
Cabinet Standard::
ANS/EIA RS-310-D
Color:
Grey Or Black
Two Ends Doors:
Sliding /manual Doors Optional
Static Payload:
1100kg
Custom Logo Lable:
Yes
Name:
Data Center Rack Cold Aisle Containment
Material:
2.0mm Cold Rolled Steel
Hot Air Containment:
Included
Cabinet Standard::
ANS/EIA RS-310-D
Color:
Grey Or Black
Two Ends Doors:
Sliding /manual Doors Optional
Static Payload:
1100kg
Custom Logo Lable:
Yes
Cold Aisle Micro Modular Data Center With Modular UPS And In Row AC Units

Micro Module Data Center Modular Data Center With Modular UPS And In Row AC Units

 

Product Introduction                                   

Coolnet module Data Center is a new generation of data center solutions developed by Coolnet, we are creating an innovative way to solve your growing mission challenges and data center infrastructure needs. With its high performance, high availability, high density, large-scale expansion, easy management and wide compatibility, modular data center has greatly shortened the construction cycle of customers' data centers; Significantly improved energy efficiency, reduced construction investment and operating costs, and provided customers with high Cost-effective, high-security products and solutions.

 

Benefits                                                           

Fast deployment

Full integration of IT cabinet, UPS, battery, power distribution and precision cooling system. The main body of the building and the basic water and electricity construction are completed at one time, and the micro-modules are flexibly deployed as needed. Modular components following international standards are quick to play within 7 days and greatly shorten the business on line cycle.

 

Quick and economical

Micro data center can be directly installed on the cement floor, and the machine room can be simply decorated; the engineering is commercialized, and all products are produced in modular form; the capacity can be expanded as needed to reduce the initial investment.

Cold Aisle Micro Modular Data Center With Modular UPS And In Row AC Units 0

 

 

 

 

 

Feature

Smart monitoring system

Centralized monitoring platform makes us know the data center environment, power and temperature & humidity status in real-time.

Powerful reporting capabilities.

365 days 7x24-hour unattended, remote monitoring. Minimize IT operation and maintenance costs.

The dynamic environment monitoring system monitors the infrastructure in an all-round way, alerts abnormal conditions in time, and is safe and secure.

 

Safety and reliability

N+1/2N redundant design. The continuous power supply with back up battary guarantees stable IT equipment operation.

Multi-stage automatic alarm function. Real-time system condition monitoring.

Containment top panel can be opened by the fire system.

 

Cooling solution

Air-cooled module solution

Applicable to various medium and small data centers, such as: operator data centers, data centers of various industries (finance, government, energy, medical, etc.) and other enterprise-level data centers.

Chilled water module

It is suitable for all kinds of large and medium data centers with chilled water hosts, such as: Internet data centers, operator data centers, data centers in various industries (finance, government, energy, medical, etc.) and other enterprise-level data centers.

 

 

Main Basic Unit Introduction

 

Aisle Containment -Modular design

Adopting modular unit design concept, each unit can be installed and disassembled independently, and can be closely connected with adjacent units, which is convenient for disassembly and assembly; at the same time, it is also suitable for maintenance and management of other equipment on the channel.

Good sealing

All unit modules in the hot and cold aisle system are connected precisely, and the parts are sealed with good sealing tops or sponge strips, which not only maintains the aesthetics, but also prevents the leakage of cold air in the cold aisle.

Good light transmission

The system is composed of toughened glass with strong light transmittance

 

Power Supply- Modular UPS

According to the power supply requirements of large and medium-sized data centers, a modular UPS solution has been introduced, which can be flexibly configured with 80-300kVA modular UPS according to the customer's system power supply requirements. The module adopts advanced high-frequency switching technology, fully digital DSP control technology and the world’s leading active PFC and LLC topologies to achieve high input power factor, accurate output current sharing performance, and reliable monitoring and management system. The equipment provides safe, reliable and pure AC power.

 

 

Cooling System - In Row Air Conditioning Unit

Inverter In Row air conditioners are tailor-made high-density cabinets, adopts advanced frequency conversion technology and uses the environmentally friendly refrigerant R410A. The output cooling capacity is adjusted in real time according to the change of the detected load, to avoid frequent start and stop, and to ensure the temperature of the computer room environment.
Compared with fixed frequency air conditioners, the annual energy saving rate of variable frequency inter-train air conditioners can reach 29%

 

Monitoring System

The monitoring system system has the characteristics of simple configuration, strong access, and high reliability. It can manage all power, environment, and cooling in data center, integrate mainstream brand access control, video and other security systems, through distributed collection, high concurrent processing capabilities Meet the needs of networked monitoring and management of multiple computer rooms, allowing data center operation and maintenance personnel to control the operation safety of the computer room in real time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Applicaton Scence