Product Details
Place of Origin: CHINA
Brand Name: COOLNET
Certification: CE,ISO
Model Number: CNER01-CNER20
Payment & Shipping Terms
Minimum Order Quantity: 5units
Price: USD 120-2200/unit
Packaging Details: Export carton packing
Delivery Time: 5-10 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 3000 unit per month
Output Voltage: |
220/230/240VAC,220v,200/208/220v/230v/240VAC,110VAC |
Protection: |
Short Circuit,Overcurrent,Overvoltage,overload/overshort/discharge/charge/short Circuit |
Type: |
On-line,rackmount,rack Mount Online Ups |
Application: |
Networking,Computer,Telecommunications,manufacture,education Etc. |
Phase: |
Single Phase,Single/Three Phase,Three Phase |
Weight: |
4.15-55kg |
Waveform: |
Pure Sine Wave |
Power Factor: |
0.8,09,0.99 |
Output Current: |
10-20A |
Frequency: |
50/60HZ |
Output Voltage: |
220/230/240VAC,220v,200/208/220v/230v/240VAC,110VAC |
Protection: |
Short Circuit,Overcurrent,Overvoltage,overload/overshort/discharge/charge/short Circuit |
Type: |
On-line,rackmount,rack Mount Online Ups |
Application: |
Networking,Computer,Telecommunications,manufacture,education Etc. |
Phase: |
Single Phase,Single/Three Phase,Three Phase |
Weight: |
4.15-55kg |
Waveform: |
Pure Sine Wave |
Power Factor: |
0.8,09,0.99 |
Output Current: |
10-20A |
Frequency: |
50/60HZ |
Online Rack Mount Uninterruptible Power Supply Ups 1KVA 3KVA 6kva 10kva 15kva 20kva
High frequency on line 1 kVA ~ 20 kVA ( single phase inlet and single phase
outlet/three phase inlet and single phase outlet/three phase inlet and three phase outlet)
Flexible, reliable and perfect compatible server cabinet.
Coolnet rack type UPS is the double transformation on-line technology, support more than 3 sets parallel work, and support the function of sharing battery pack when in parallel mode; online UPScan provide the optimal power environment for the load. Regardless of voltage accuracy, input noise filtering, zero switching time and compatible with the standard terms of service cabinet, Rack UPS is the best choice.
Character and Advantage
♦Support LBS control in sync;
♦Have the function of fan speeding control with intelligence;
♦Comprehensive electrical isolation protection and bypass protection;
♦Support bypass maintenance (three phase inlet and single phase outlet/three phase inlet and three phase outlet);
♦Large LCD Chinese/English display interface, user friendly;
♦Make automatic alarm, self-detection, find problems easily in time come true;
♦Three - stage extended charge design to ensure superior battery performance;
♦Only online UPS, and output high quality sine wave power that provide the user a better power supply protection;
♦Wider range of input voltage that working under large fluctuations grid environment, can be in commercial power
♦mode without switching to battery mode, which can protect the battery lifespan
Design Concept
♦Long-term power supply design
Rack UPS provide long backup time unit for users to choose: through configure different battery pack capacities, can meet the user's requirements for different backup time.
♦Can be used with large motor
Wide input voltage and frequency range that make Rack UPS compatible with main brand generator. It expand the application environment, meanwhile effectively remove the harmful power made by the generator, also supply a pure, safe and stable power for the load.
♦Configure standard battery module
Rack UPS configured standard battery module(For user selection). Standard battery modules are used in high quality VRLA maintenance free lead-acid battery, with high battery quality to ensure the safety and reliability of UPS using.
♦Zero transition time
When the city power outage or recovery, it do not need conversion time for the Rack UPS switching between the power mode and the battery mode, thus effectively ensuring the reliability of load operation and data storage.
♦Input power factor correction
Rack UPS have Input power factor correct function, the Input power factor can reach to above 0.99% under full loading condition,which protect use's grid environment from pollution.
♦DC Start
In the case of power cut, if need to start computer or other load devices by Rack UPS,Rack UPS can use battery to carry on DC Start, so that make the use of Rack UPS more convenient and reliable.
♦Auto restart function
Once the city power abnormal, it will enter into battery mode to supply power until the end of power supply, then the Rack UPS will shut down automatically; after the city power back to normal, UPS will activate
♦Configure smart slot
Rack UPS equipped with an intelligent slot,users can purchase SNMP card or other general accessories. Make centralized monitoring and remote management functions come true through SNMP internet management.
Data Sheet
Model | CNER-1101(L) | CNER-1102(L) | CNER-1103(L) | CNER-1106L | CNER-1110L | ||||||||||||
Capacity | 1KVA/0.8kW | 2KVA/1.6kW | 3KVA/2.4kW | 6KVA/4.8kW | 10KVA/8kW | ||||||||||||
Input | |||||||||||||||||
Connection Mode | Single Phase + Ground | ||||||||||||||||
Input Voltage | 200/208/220/230/240VAC | ||||||||||||||||
Voltage Range | 100~300VAC | ||||||||||||||||
Frequency | 40~70Hz | ||||||||||||||||
Power factor | >0.99 | ||||||||||||||||
Output | |||||||||||||||||
Output Voltage | 200/208/220/230/240VAC | ||||||||||||||||
Voltage regulation | ±1% | ||||||||||||||||
Frequency | Synchronous correction range | 46~54Hz/56~64Hz | |||||||||||||||
Battery Model | 50Hz±0.1Hz/60Hz±0.1Hz | ||||||||||||||||
Distortion (THDU) | ≤0.3% | ||||||||||||||||
Peak Coefficient | ≥3:1 | ||||||||||||||||
Overload Capacity | 110%,convey to bypass after 1h;125%,convey to bypass after 10min;150%,convey to bypass after 1min. | ||||||||||||||||
Time switching | Electric City/Battery | 0ms | |||||||||||||||
Inverter/Bypass | <4ms (standard environment) | 0ms | |||||||||||||||
Battery | |||||||||||||||||
Standard Machine | Battery Cells | 2 | 4 | 6 | / | ||||||||||||
Charging Current | 1.0A (Max) | / | |||||||||||||||
Battery Model | 12V,9Ah | / | |||||||||||||||
Long Lasting | Battery Cells | 3 | 6 | 8 | 16(16-20 optional) | ||||||||||||
Charging Current | 1A/2A/4A/6A settable | ||||||||||||||||
Battery Model | Depends on the applicant | ||||||||||||||||
Efficiency | |||||||||||||||||
City Electricity Model | >91% | >93% | |||||||||||||||
Battery Model | >91% | >93% | |||||||||||||||
Display Interface | |||||||||||||||||
LCD/LED | Loading Size, Battery Capacity, City Electricity Mode, Battery Mode, Bypass Mode, Fault Indication | ||||||||||||||||
Control Management | |||||||||||||||||
Intelligent RS-232/USB | Support Windows 2000/2003/XP/Vista/2008,Windows 7/8,Linux,Unix and MAC | ||||||||||||||||
Option SNMP | Support SNMP Internet Management | ||||||||||||||||
Environment | |||||||||||||||||
Temperature | 0~40℃ | ||||||||||||||||
Relative Humidity | 0~95% (Non Condensing) | ||||||||||||||||
Noise | <50dB@1m | <55dB@1m | <58dB@1m | ||||||||||||||
Physical Character | |||||||||||||||||
Standard Machine | Size: Width*Depth*Height(mm) | 438*310*88 | 438*410*88 | 438*630*88 | / | / | |||||||||||
Net Weight(kg) | 12 | 18 | 29 | / | / | ||||||||||||
Long Lasting | Size:Width*Depth*Height(mm) | 438*310*88 | 438*410*88 | 438*530*88 | 438*580*133 | ||||||||||||
Net Weight(kg) | 5 | 7 | 8 | 12 | 16 |
Model | CNER-3110L | CNER-3115L | CNER-3120L | ||||
Capacity | 10kVA/8kW | 15kVA/12kW | 20kVA/16kW | ||||
Input | |||||||
Connection Mode | Three-phase + four wire | ||||||
Rated Voltage | 380/400/415VAC | ||||||
Voltage Range | 285~520VAC@100%Load; 176~520VAC@50%Load | ||||||
Frequency | 40~70Hz | ||||||
Power factor | ≥0.99 | ||||||
Output | |||||||
Output Voltage | 200/208/220/230/240VAC | ||||||
Voltage regulation | ±1% | ||||||
Frequency | Synchronous correction range | 46~54Hz/56~64Hz | |||||
Battery Model | 50Hz±0.1Hz/60Hz±0.1Hz | ||||||
Distortion (THDU) | ≤2%( Linear load ), ≤3% ( Non-liner load ) | ||||||
Distortion (THDU) | ≤0.3% | ||||||
Peak Coefficient | ≥3:1 | ||||||
Overload Capacity | 110%, convey to bypass after 1h; 125%, convey to bypass after 10min; 150%, convey to bypass after 1min. | ||||||
Time switching | Electric City/Battery | 0ms | |||||
Inverter/Bypass | 0ms | ||||||
Battery | |||||||
Battery Cells | 20 | ||||||
Charging Current | 1A/2A/4A/6A Settable | ||||||
Battery Mode | Depends on the applicant | ||||||
Efficiency | |||||||
City Electricity Mode / Battery Mode | ≥93% | ||||||
ECO Mode | ≥96% | ||||||
Display Interface | |||||||
LCD/LED | Loading Size, Battery Capacity, Electric City Mode, Battery Mode, Bypass Mode, Fault Indication | ||||||
Control Management | |||||||
Intelligent RS-232/USB | Support Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix and MAC | ||||||
Option SNMP | Support SNMP Internet Management | ||||||
Environment | |||||||
Temperature | 0~40℃ | ||||||
Relative Humidity | 0~95% (Non Condensing) | ||||||
Noise | <60dB@1m | <65dB@1m | |||||
Physical Character | |||||||
Size: Width*Depth*Height(mm) | 438*668*133 | 438*668*266 | |||||
Net Weight(kg) | 22 | 45 | |||||
Model | X1-3110L | X1-3115L | X1-3320L | ||||
Capacity | 10kVA/8kW | 15kVA/12kW | 20kVA/16kW | ||||
Input | |||||||
Connection Mode | Three-phase + four wire | ||||||
Rated Voltage | 380/400/415VAC | ||||||
Voltage Range | 285~520VAC@100%Load; 176~520VAC@50%Load | ||||||
Frequency | 40~70Hz | ||||||
Power factor | ≥0.99 | ||||||
Output | |||||||
Output Voltage | 380/400/415VAC | ||||||
Voltage regulation | ±1% | ||||||
Frequency | Synchronous correction range | 46~54Hz/56~64Hz | |||||
Battery Model | 50Hz±0.1Hz/60Hz±0.1Hz | ||||||
Distortion (THDU) | ≤2 %( Linear load ), ≤3% ( Non-liner load ) | ||||||
Distortion (THDU) | ≤0.3% | ||||||
Peak Coefficient | ≥3:1 | ||||||
Overload Capacity | 110%, convey to bypass after 1h; 125%, convey to bypass after 10min; 150%,convey to bypass after 1min. | ||||||
Time switching | Electric City/Battery | 0ms | |||||
Inverter/Bypass | 0ms | ||||||
Battery | |||||||
Battery Cells | 20 | ||||||
Charging Current | 1A/2A/4A/6A Settable | ||||||
Battery Mode | Depends on the applicant | ||||||
Efficiency | |||||||
City Electricity Mode / Battery Mode | ≥93% | ||||||
ECO Mode | ≥96% | ||||||
Display Interface | |||||||
LCD/LED | Loading Size, Battery Capacity, Electric City Mode, Battery Mode, Bypass Mode, Fault Indication | ||||||
Control Management | |||||||
Intelligent RS-232/USB | Support Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix and MAC | ||||||
Option SNMP | Support SNMP Internet Management | ||||||
Environment | |||||||
Temperature | 0~40℃ | ||||||
Relative Humidity | 0~95% (Non Condensing) | ||||||
Noise | <60dB@1m | <65dB@1m | |||||
Physical Character | |||||||
Size: Width*Depth*Height(mm) | 438*668*133 | 438*668*266 | |||||
Net Weight(kg) | 43 | 46 |