Name: |
Data Center Rack Cold Aisle Containment |
Material: |
2.0mm Cold Rolled Steel |
Hot Air Containment: |
Included |
Cabinet Standard:: |
ANS/EIA RS-310-D |
Color: |
Grey Or Black |
Two Ends Doors: |
Sliding /manual Doors Optional |
Static Payload: |
1100kg |
Custom Logo Lable: |
Yes |
Name: |
Data Center Rack Cold Aisle Containment |
Material: |
2.0mm Cold Rolled Steel |
Hot Air Containment: |
Included |
Cabinet Standard:: |
ANS/EIA RS-310-D |
Color: |
Grey Or Black |
Two Ends Doors: |
Sliding /manual Doors Optional |
Static Payload: |
1100kg |
Custom Logo Lable: |
Yes |
All In One High Density Optimized Dedicated Modular Data Center Solution For IT Devices
Product Introduction Micro module data center includes cooling modules, distribution modules and power supply, as well as modules for network, wiring, monitoring, and fire fighting.
Benefits |
Features
Hot and cold aisle containment Precision in-row air conditioners are used for near-end cooling, combined with airflow containment components. The air conditioners are placed side by side with the cabinets, close to the cabinets, and directly cool the service cabinets. Fast deployment Full integration of IT cabinet, UPS, battery, power distribution and precision cooling system. The main body of the building and the basic water and electricity construction are completed at one time, and the micro-modules are flexibly deployed as needed. Modular components following international standards are quick to play within 7 days and greatly shorten the business on line cycle. Modular construction Knocked down components shipped from the factory with an easy-to-assemble at site design. Part-wise build up from the base with lowest dependency on physical infrastructure at site. Safety and Reliability N+1/2N redundant design. The continuous power supply with back up battary guarantees stable IT equipment operation. Multi-stage automatic alarm function. Real-time system condition monitoring. Containment top panel can be opened by the fire system. |
Main Basic Unit Introduction
Rack |
Air Supply Method
Technical Specification
Equipment System | Item | Parameter |
System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets |
1200mm enclosed cold/hot aisle Single-row cabinets | ||
Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | |
Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U |
Protection Class | IP20 | |
Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight |
Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) |
UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | |
Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | |
Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) |
Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | |
Power Supply | 3Phase 380VAC,50Hz | |
Air Supply | Front Supply | |
Type | Enclosed Hot/Cold Aisle | |
Protection | IP20 | |
Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm |
Equipment monitoring | Power supply, battery, power distribution, air conditioning |