6KW Data Center Precision Air Conditioner 50HZ 6000W IT Room Air Conditioning

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE/ISO9001

Model Number: M13

Payment & Shipping Terms

Minimum Order Quantity: 1Unit

Price: USD3000.00-30000.00/unit

Packaging Details: Wooded

Delivery Time: 20-40Working Days

Payment Terms: T/T, L/C

Supply Ability: 1000 Unit/Month

Get Best Price
Highlight:

50HZ Data Center Precision Air Conditioner

,

6KW IT Room Air Conditioning Unit

Cooling Capacity:
5-13KW
Operating Voltage:
380/400 VAC,230 VAC,220V
Application:
Computer Room,Server Room,Power Distribution Room And Battery Room High Precision Lab,Measuring Room Industrial Control Room
Color:
Black/Grey White/other Custom Colors
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
Front Flow
Cooling Capacity:
5-13KW
Operating Voltage:
380/400 VAC,230 VAC,220V
Application:
Computer Room,Server Room,Power Distribution Room And Battery Room High Precision Lab,Measuring Room Industrial Control Room
Color:
Black/Grey White/other Custom Colors
Power:
3N-380V-50Hz,220v/50hz/60hz
Airflow:
Front Flow
6KW Data Center Precision Air Conditioner 50HZ 6000W IT Room Air Conditioning

6KW Data Center Precision Air Conditioner,50HZ Data Center Precision Air Conditioner,6000W IT Room Air Conditioning

 

Product Introduction                                                           

Cool-smart series constant temperature and humidity precision air conditioner is with modular design, high EER, large screen human-computer interface and intelligent control system. It has options of air-cooled, water-cooled, chilled water and double source cooled.

 

 

The Cool-Smart Series computer room air conditioner is designed for small and medium-sized computer rooms, base stations, equipment rooms, etc., Cool-Smart has the characteristics of high air volume and small enthalpy with high reliablity , high efficiency, long working life and energy saving advantages.

 

 

 

 

6KW Data Center Precision Air Conditioner 50HZ 6000W IT Room Air Conditioning 0

 

Component with High-Quality Control                                 

Single Phase 6.4kW Precision Air Conditioning DX Units For Small Data Center And It Equipment Room 2

Cabinet

The cabinet ensures the protection of the unit under any shipping situation and operational environment with its distinctive frame design and black steel frame, which showcases impeccable manufacturing technology, professional design, and exquisite look.

 

 

Expansion valve

Expansion valve uses highly reliable, stable, and exact thermal expansion valves to precisely control the delivery of refrigerant. We use cutting-edge electronic expansion valves in high-performance, precise air conditioning systems in order to reduce the energy consumption for refrigeration equipment.

 

Advantages                                                                               

 

 

High energy efficiency

Heat ratio is up to 91%. Compressor energy efficiency ratio is over 3.1, and chilled water cooled unit’s cooling energy efficiency is larger than 25. The optimal and high efficiency compressor and fans. “W/M” type evaporator with super large heat exchange area. Independent air duct design can reduce air resistance significantly and minimize fans power. Variable frequency design on ODU is more efficient and has longer working life. Advanced control logic can effectively avoid competitive running and output cooling capacity according to actual cooling capacity demand.

 

 

High reliability

Provide Constant temperature & humidity, cleanness precision environment to ensure the main equipment in good running condition.

24-hour running design guarantee main equipment operation safety.

All units had passed a severe running test before delivery, which can ensure units’ high reliability.

 

 

  Server Room/Data Center Precision Cooling Unit System Solutions 2

 

Technical Parameter                                                            

 

Model

M04

M06

M08

M13

M16

M20

Power Supply

220V1Ph-50Hz

380V3Ph-50Hz

Air discharge

Up Front/Down

Technical Data Sheet

AC Fan

Total cooling capacity-KW

4.2

6.4

7.5

12.5

16.8

20.2

Sensible cooling capacity-KW

3.9

5.8

6.9

11.3

15.3

18.3

Unit FLA-A(heating, humidifying type)

20.0

25.0

16.8

22.0

23.5

28.6

Compressor Quantity

1

Fan Quantity

1

Air Volume-m3/h

1600

1900

2300

3600

5100

6500

Heater Capacity-KW

3.0

3.0

6.0

6.0

6.0

6.0

Humidification-kg/h

3

3

3

3

6

6

Power of humidifier-KW

2.3

2.3

2.3

2.3

4.5

4.5

Outdoor Condenser

Model

SCA020

SCA020

SCA030

SCA030

SCA050

SCA050

Standard unit operating temperature range-℃

-15-45℃

Low Temperature Components Operating Temperature Range-℃

-40-45℃

 

Certificates                                                                                    

6KW Data Center Precision Air Conditioner 50HZ 6000W IT Room Air Conditioning 3

 

Factory Details                                                        

6KW Data Center Precision Air Conditioner 50HZ 6000W IT Room Air Conditioning 4

 

Packing & Delivery                                                                     

6KW Data Center Precision Air Conditioner 50HZ 6000W IT Room Air Conditioning 5

 

Cases                                                                                                          

6KW Data Center Precision Air Conditioner 50HZ 6000W IT Room Air Conditioning 6