Intelligent Rack Data Center Cooling System With Environment Monitoring System

Product Details

Place of Origin: China

Brand Name: Coolnet

Certification: CE ISO

Model Number: Mirco data center

Payment & Shipping Terms

Minimum Order Quantity: 1pcs

Price: USD3000-10000/pcs

Packaging Details: Standard export package

Delivery Time: 20-35 days

Payment Terms: L/C, T/T

Supply Ability: 200 SETS PER MONTH

Get Best Price
Highlight:

CE Approved Server Rack Cooling System

,

IP5X Data Center Cooling System

Voltage:
380v/220v,110-220v/50-60Hz,220V/50Hz
Cooling:
DC Inverter Rack Mounted PAC Units
Refrigerant:
R134a,R407C,R22,R410A
Power:
Rack PDU And UPS
Voltage:
380v/220v,110-220v/50-60Hz,220V/50Hz
Cooling:
DC Inverter Rack Mounted PAC Units
Refrigerant:
R134a,R407C,R22,R410A
Power:
Rack PDU And UPS
Intelligent Rack Data Center Cooling System With Environment Monitoring System

Intelligent Rack Data Center Cooling System With Environment Monitoring System

 

Product Introduction                                                                  

Coolnet rack data center, which integrates all infrastructure facilities such as power supply and distribution, cooling, monitoring and cabling into one fully enclosed IT cabinet, provides an unprecedented excellent working environment and reliable guarantee platform for small and micro IT room application scenarios. Support single cabinet, single row and other flexible deployment methods. With high density and modularity, high reliability and availability, flexible configuration and rapid deployment, easy installation and green energy saving, perfect intelligent monitoring and other characteristics. Intelligent Rack Data Center Cooling System With Environment Monitoring System 0

Intelligent Rack Data Center Cooling System With Environment Monitoring System 1

Advantage                                                                                      

Intelligent Rack Data Center Cooling System With Environment Monitoring System 2

    With the wisdom terminal as the core, the internal integration of the power distribution system, cooling system, fire protection system, access control system, monitoring system and other infrastructure necessary for the server room. Nanjing Jizuo Network Technology Co., Ltd. replaces engineering with products, easy and quick installation, ready to use; and detaches the server room from the environment, adapts to a variety of application scenarios, flexible in use, economical and efficient, safe and reliable.

Rack intelligent cabinet data center will build enterprise data center in almost any working environment with less time and lower cost, and bring stable and reliable power, cooling, security and monitoring. Compared with traditional data centers, the new modular data center can save up to 30% of the cost and 50% of the space footprint.

 

 

Technical Parameter                                                                       

 

Model EC08 EC12 EC20 ERx
Power 3KVA 3-6KVA 6-30KVA
Number of cabinets 0.8m high cabinet, available space 8U 1.2m high cabinet, available space 16U Standard 42U cabinet, free space 30U 2-10 standard 42U glass door cabinets
Enclosed cabinet Glass door, IP5X, full cold and hot channel sealing
Power supply 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
Refrigeration Unique air duct design, without air conditioner and outdoor unit Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

 