Highlight:
Rate Voltage:
380/400/415VAC(L-L),220/230/240VAC(L-N)
Rate Freq:
50/60Hz
Battery Rate Voltage:
±240VDC(adjustable For 32-44 Sections)
System Display:
LED + 7 Inch Touch LCD
Input PF:
>0.99
Environment:
0-40℃(operation);-25~70(storage);0-95% (Humidity,non-condensing)
Noise(dB)(1 Meter):
65dB @ 100% Load, 62dB @ 45% Load
Warranty:
12 Months
Battery Rate Voltage:
±240VDC
Battery Charging Accuracy:
±1%
Rate Voltage:
380/400/415VAC(L-L),220/230/240VAC(L-N)
Rate Freq:
50/60Hz
Battery Rate Voltage:
±240VDC(adjustable For 32-44 Sections)
System Display:
LED + 7 Inch Touch LCD
Input PF:
>0.99
Environment:
0-40℃(operation);-25~70(storage);0-95% (Humidity,non-condensing)
Noise(dB)(1 Meter):
65dB @ 100% Load, 62dB @ 45% Load
Warranty:
12 Months
Battery Rate Voltage:
±240VDC
Battery Charging Accuracy:
±1%
Revolutionize Your Power Management Strategy With CNM Series Rack-Mounted Modular UPS

Revolutionize Your Power Management Strategy With CNM Series Rack-Mounted Modular UPS
 

 


Product Description                               

Modular UPS adopts standard structural design, each system consists of a power module, monitoring module, and static switch. The power modules can be connected in parallel to share the load evenly among them. In case of failure, it will automatically exit the system and other power modules will take the load, which can be expanded both horizontally and vertically. The unique redundant parallel technology makes the equipment without a single point of failure to ensure the highest availability of power supply. All modules can be hot-plugged and replaced online, and maintenance is the safest power protection solution.

Revolutionize Your Power Management Strategy With CNM Series Rack-Mounted Modular UPS 0


 

 

Product Feature                                       

 

Revolutionize Your Power Management Strategy With CNM Series Rack-Mounted Modular UPS 1

 

Multiple operating modes

The product has a variety of systems to choose from, easy to operate, and can be realized in a variety of inlet and outlet modes: 1/1, 1/3, 3/1, or 3/3, input frequency can be set to 50Hz and output frequency can be set to 60Hz, the output voltage can be set to 220V, 230V, 240V, if you configure the input and output transformers to meet the global scope of all countries and regions of power supply needs.

 

Small size, high power density

High working efficiency and high power density are the most important features. It can provide 5KVA (4000W), 10KVA (8000W), 15KVA (12KW) and 20KVA (16KW) power output.

 

Expandability, easy to install, maintain, replace, and upgrade

The model consists of various modules, which can realize the function of hot plugging and dialing. The rack of each module can be completely separated, which is convenient for users to expand or reduce the capacity in the future, and easy to use. Online replacement and online maintenance can be realized, which reduces the difficulty of maintenance and the time of maintenance. The size of each module is designed by the standard 19-inch structure, so that the appearance of the whole machine is consistent with the standard rack, beautifying the appearance of the machine, and the module can be common with the standard rack.

 

Redundancy, decentralized parallel logic control

Parallel control between the modules adopts decentralized logic control, no host and slave, any one module dial out or insert will not affect the normal work of other modules, on-demand N +1, N + X redundancy system, reducing the risk factor of the system itself and the load is the load by the UPS to protect the time of the overall increase. Not only increases the reliability of the whole machine but also simplifies the user's maintenance difficulties.

 

 

Product Advantages                                  

 


First, "modular redundant parallel" technology to avoid waste of resources. In the industry users of the information network power supply system construction, often on the high-end UPS capacity to produce the wrong, or too low or too high expectations, the results may lead to high procurement costs, can not meet the load needs or cause resources, space and energy waste and so on. Modular UPS through the expandable module structure effectively solves this problem, it can help users in future development is not clear in the case of phased construction and investment.


Second, high security, easy to maintain the hot-swap technology breaks through the application bottleneck. Traditional high-end UPS during routine maintenance, equipment maintenance is required to take the way to turn bypass, and the load in this case is not protected by the UPS. Therefore, if power interruption, overload and other faults occur at this time, will cause serious losses, and its maintenance process will be relatively cumbersome, and unfavorable time. Modular UPS systems used in the hot-swap technology can allow a single module without the need for power outages under the premise of arbitrary entry or exit from the parallel unit, thus realizing the parallel system of online maintenance, while no special instruments or techniques can be carried out.


Third, the power phase multiple system technology reduces procurement and management costs. Traditional high-end UPS power input and output phases are fixed, so users often increase the number of UPS to take into account the different phases and capacity in the construction of the power supply system. Under the modular UPS system, the power supply phase multiple system technology can be used to change the constraints caused by the past unity, the user no longer needs to consider how to purchase different phases or capacities of the UPS products to adapt to the needs of the system.

Revolutionize Your Power Management Strategy With CNM Series Rack-Mounted Modular UPS 2

 

 

 

Data Sheet                                                   

Model CNM 020/10 030/15 040/20 040/10 045/15 060/15 080/20 090/15 120/20
Rate Power 20KVA/20KW 30KVA/30KW 40KVA/40KW 40KVA/40KW 45KVA/45KW 60KVA/60KW 80KVA/80KW 90KVA/90KW 120KVA/120KW
Main input
Input 3P5W(3P+N+PE)
Rate Voltage 380/400/415VAC(L-L);220/230/240VAC(L-N)
Rate Freq 50/60Hz
Input PF >0.99
Current Distortion THDi<3%(100%Linear load)
Voltage Range 304-478VAC(L-L)full load;304-228VAC(L-L)power derate from 100%to 75%
Freg.Range 40-70Hz
Battery
Rate voltage ±240VDC(adjustable for 32-44 sections)
Charging Capacity 20%*Pout
Charging Accuracy ±1%
Bypass
Rate Voltage 380/400/415VAC(L-L);220/230/240VAC(L-N)
Voltage Range Range:-40%-+25%,Settable,default-20%~+15%
Overload 110%,long time operation;110%<load<125%,5 mins
125%<load<150%,1min;>150%,1second
Inverter
Rate Voltage 380/400/415VAC(L-L);220/230/240VAC(L-N)
Rate Freq 50/60Hz
Output PF 1
Voltage Accuracy ±1.0%
load Response <5%(20%-80%-20%step load)
Recovery Time <20ms(0%-100%-0%step load)
Output THDu <1%(linear load),<5%(non-linear load according to IEC 62040-3)
Overload 110%,1 hour;125%,10 mins;150%,1min;>150%,200ms
Frequency Accuracy 0.1%
Synchronize Window Settable,±0.5Hz-±5Hz,default±3Hz
Slew Rate Settable,0.5Hz/S-3Hz/S,default 0.5Hz/S
Phase Accuracy 120°±0.5°
System
Efficiency Normal Mode≥96%;Battery Mode≥96%
Display LED+7inch touch LCD
Certification-Safety IEC62040-1,IEC60950-1
Certification-EMS IEC62040-2;IEC61000-4-2(ESD);IEC61000-4-3(RS);IEC61000-4-4(EFT);IEC61000-4-5(Surge)
IP Degree IP20
Configuration USB,RS232,RS485,Dry contact,Cold start
Option SNMP card,AS400 card,Parallel kit,LBS,Air filter,Bottom entry kit,Wheels kit
Environment 0-40℃(operation);-25~70(storage);0-95%(Humidity,non-condensing)
Noise(dB)(1meter) 65dB @100%load,62dB @45%load
Dimension
Cabinet(W*D*H)mm 482*700*396(9U,
wheels not included)
482*700*662(15U,
wheels not included)
482*700*840(19U,
wheels not included)
Module(W*D*H)mm 440*555*85(2U)

 

 

Applications                                           

  • Data centers
  • Telecommunications networks
  • Industrial facilities
  • Medical facilities
  • Financial institutions
  • Government agencies
  • Educational institutions
Revolutionize Your Power Management Strategy With CNM Series Rack-Mounted Modular UPS 3


Packing&Shipping                                  

 

Revolutionize Your Power Management Strategy With CNM Series Rack-Mounted Modular UPS 4

Factory View                                        

 

Revolutionize Your Power Management Strategy With CNM Series Rack-Mounted Modular UPS 5