3.5-10.5KW Cooling Capacity Micro Data Center Rack Mountable

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE ISO

Model Number: MDC 8U 16U 30U

Payment & Shipping Terms

Minimum Order Quantity: 1PCS

Price: USD3000-10000/pcs

Packaging Details: Standard export package

Delivery Time: 20-35 days

Payment Terms: L/C, T/T

Supply Ability: 200 SETS PER MONTH

Get Best Price
Highlight:

3.5KW Cooling Data Center Rack

,

Data Center Rack Mountable

,

10.5KW Cooling Data Center Rack

Name:
Cabinet System Units
Application:
Network Closets, Telecom Sites , Edge Computing
Cabinet Quatities:
Single Cabinet/Multiple Cabinets
Operating:
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V
UPS Type:
Rack Mounted Type
Cabinet Type:
26U 42U
Name:
Cabinet System Units
Application:
Network Closets, Telecom Sites , Edge Computing
Cabinet Quatities:
Single Cabinet/Multiple Cabinets
Operating:
380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V
UPS Type:
Rack Mounted Type
Cabinet Type:
26U 42U
3.5-10.5KW Cooling Capacity Micro Data Center Rack Mountable

3.5-10.5KW Cooling Capacity Micro Data Center Rack Mountable

 

Product Introduction                                            

Ranging in size from a single 19-inch rack to a 40-foot shipping container, micro data centers are small enough to be deployed in locations where a traditional data center would be impractical. This allows organizations to solve the low-latency data processing and storage challenge in a cost-effective way.

While there is no single standard for micro data center design, an MDC must be able to house the full technology stack an application requires. As a result, these components are common in MDCs

3.5-10.5KW Cooling Capacity Micro Data Center Rack Mountable 0

3.5-10.5KW Cooling Capacity Micro Data Center Rack Mountable 1

Advantages                                                              

3.5-10.5KW Cooling Capacity Micro Data Center Rack Mountable 2

By bringing data processing closer to end-users and enabling organizations to distribute their data center footprint, MDCs deliver several business benefits including:

 

Low latency

This is the fundamental issue MDCs help address. By bringing the “client” and “server” computers geographically closer, MDCs can lower latency significantly.


Increased resilience

A failure, such as a cut MPLS (Multiprotocol Label Switching) line, that leads to a traditional data center becoming inaccessible can bring production to a halt. Even if fault tolerance is part of the design, it’s often N+1 or 2N at best. With MDCs, having dozens of failover options becomes feasible.


Faster deployment times

Often, micro data centers can be shipped partially or fully assembled. Additionally, because their small size makes accessing adequate space and power easier, MDC provisioning is significantly faster than a traditional data center build-out.


Standardization

By enabling a standardized and repeatable design, MDCs can reduce opex and maintenance costs.


Scalability

Micro data centers allow businesses to incrementally scale up based upon demand. This allows for a more elastic and agile approach to infrastructure that is conducive to rapid growth.

 

Application                                                                 

  • Edge Computing
  • As a computing node in remote and branch offices(Banks, Telecommunication companies, etc.)
  • As a floor distributor
  • In small business and enterprises

 

3.5-10.5KW Cooling Capacity Micro Data Center Rack Mountable 3

 

Technical Parameter                                                  

 

Model EC08 EC12 EC20 ERx
Power 3KVA 3-6KVA 6-30KVA
Number of cabinets 0.8m high cabinet, available space 8U 1.2m high cabinet, available space 16U Standard 42U cabinet, free space 30U 2-10 standard 42U glass door cabinets
Enclosed cabinet Glass door, IP5X, full cold and hot channel sealing
Power supply 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
Refrigeration Unique air duct design, without air conditioner and outdoor unit Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

 