Precision In Row Air Conditioning Meets Data Center Cooling Needs

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: CYAS40D/U

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

In Row Air Conditioning Unit 25KW

,

Data Center Air Cooled Unit

,

R407C In Row Air Conditioning Unit

Cooling Capacity:
25KW
Mounting:
Floor Standing
Condition:
New
Type:
Air Cooled Unit
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year
Product Name:
In Row Air Conditioning Unit
Refrigerant:
R22(R407C/R410A)
Application:
Data Center , Cold And Hot Aisle
Cooling Capacity:
25KW
Mounting:
Floor Standing
Condition:
New
Type:
Air Cooled Unit
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Operating Voltage:
380/400 VAC,230 VAC,220V
Warranty:
1 Year
Product Name:
In Row Air Conditioning Unit
Refrigerant:
R22(R407C/R410A)
Application:
Data Center , Cold And Hot Aisle
Precision In Row Air Conditioning Meets Data Center Cooling Needs

Precision In Row Air Conditioning Meets Data Center Cooling Needs

 

 

Product Introduction                       

COOLNET In-row Precision AC is an in-row air conditioner tailored for the specific cooling requirements of high-density cabinets, solving the user's local hot spot problem and suitable for a variety of different user installation conditions and cooling density requirements. The advanced DC inverter refrigeration system is adopted, and the mainstream environmentally friendly refrigerant R410A is used. The frequency adjustment is carried out in real time to ensure the stability of the computer room environment. 

 

Features                                            

 

Quick response
Close to the heat source for cooling, monitor heat load changes in real time, quickly adjust the cooling output, and adapt to the load demand.


Excellent control logic
Accurate, safe and energy-saving frequency conversion control logic ensures the accuracy and stability of the target ambient temperature and humidity, while achieving the ideal energy-saving purpose.


Premium accessories
Xingyun series SCAL.I units use high-efficiency, mature and stable well-known compressors and high-quality components to ensure the ideal performance of the whole machine.

Precision In Row Air Conditioning Meets Data Center Cooling Needs 0
Precision In Row Air Conditioning Meets Data Center Cooling Needs 1

Application                     

 

 

High thermal density data center

 

Data centers with insufficient floor heights that cannot use down-supply air or pipelines

 

Local overheating area

 

The cabinet adopts cold and hot aisle layout

Precision In Row Air Conditioning Meets Data Center Cooling Needs 2

Technical Features                               

 

High Efficiency-DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

 

High Efficiency-Electronic Expansion Valve

Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;

Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;

Fast response speed, realizing precise refrigeration;

 

High Efficiency-Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

Precision In Row Air Conditioning Meets Data Center Cooling Needs 3

 

Technica Parameter                                                                                  

 

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                              

Precision In Row Air Conditioning Meets Data Center Cooling Needs 4
 
Factory Details                                                
Precision Air Conditioning Unit In Row For Modular Data Center 6
 
Delivery & Packing                                                
Precision In Row Air Conditioning Meets Data Center Cooling Needs 6

 

 

Cases                                                                  

 

Precision Air Conditioning Unit In Row For Modular Data Center 5