In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers

Product Details

Place of Origin: CHINA

Brand Name: COOLNET

Certification: CE,ISO

Model Number: XR012A, XR023A

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: 1800-30000USD

Packaging Details: Packed in plywooden case, standard export package

Delivery Time: 10-25 working days

Payment Terms: T/T, L/C

Supply Ability: 300 PCS PER MONTG

Get Best Price
Highlight:

Precision Air Conditioning Floor Standing

,

80KW In Row Air Conditioning Unit

,

Axial Fan In Row Air Conditioner

Product Name:
In-Row Air Cooling Units
Total Cooling Capacity:
12-80KW
Application:
Data Center, Modular Data Center,Container Data Center
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Warranty:
1 Year
Type:
Row Based Precision Air Cooling System
Mounting:
Floor Standing
Voltage:
380/400 VAC,230 VAC,220V
Refrigerant:
R410A/ R407C
Color:
Black,Grey,White, Other Colors
Product Name:
In-Row Air Cooling Units
Total Cooling Capacity:
12-80KW
Application:
Data Center, Modular Data Center,Container Data Center
Fan Type:
Axial Fan,Direct Driven Or Belt Driven,direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan
Warranty:
1 Year
Type:
Row Based Precision Air Cooling System
Mounting:
Floor Standing
Voltage:
380/400 VAC,230 VAC,220V
Refrigerant:
R410A/ R407C
Color:
Black,Grey,White, Other Colors
In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers

In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers

 

Product Introduction                             

 

The in-row air conditioner is a kind of heat dissipation equipment arranged in the rack of the cabinet and installed side by side with the server cabinet. The traditional computer room air conditioner is generally far away from the heat source because it needs to adjust the temperature of the internal space of the entire room so that the effect is uneven and the energy consumption is large. However, the in-row air conditioner can be close to the heat source, it can directly dissipate heat from the heat source. Its heat dissipation efficiency is higher and it is more conducive to saving energy. Therefore, the in-row air conditioner has been more and more widely used in the cabinet in the computer room for heat dissipation.

 

Main Applications                              

  • Data center with single rack above 3kW
  • High heat density computer room
  • Partially overheated computer room
  • Modular DC
  • Container DC
  • Low PUE data center
  • Renovation of local hot spots in the computer room
In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers 0

In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers 1

Advantages & Features                        

In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers 2

EVO Control System

  • Graphic display, including the running status and the temperature/humidity of the inlet/outlet air
  • Advanced team work function, up to 32 units and easy to set network
  • Standard RS485 port, optional SNMP, TCP/IP interfaces, and GPRS with SMS
  • Standard communication protocol, optional customized specifications
Electronically Commutated Compressor
  • R410A
  • Compressor speed is infinitely variable dependent on the heat load
  • Energy saving under partial-load mode, improving energy efficiency
  • Significant reduce the start/stop frequency of the compressor
  • Improve the system reliability

Options                              

  • Transfer switch for Dual Power Input
  • Baffles
  • Low-temperature startup kits
  • GPRS SMS alarm
  • Wired temperature/humidity sensors
  • Three-way water valve
In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers 3

Product Details                                           

 

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                         

In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers 4

 

Factory Details                                                    

In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers 5

 

Delivery & Packing                                        

In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers 6

 

Cases                                            

In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers 7