In Row Air Conditioners For Data Centers And Network Management Centers

Product Details

Place of Origin: China

Brand Name: Coolent

Certification: ISO/CE

Model Number: XR023-040

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: to be Negotiated

Packaging Details: WOODEN

Delivery Time: 4W

Payment Terms: T/T

Supply Ability: 1000/Month

Get Best Price
Highlight:

Floor Standing In Row Air Conditioner

,

Data Centers In Row Air Conditioner

,

In Row Air Conditioning Unit R410A

Capacity:
20-40KW
Mounting:
Floor Standing
Application:
Modularized Data Center, High Heat Density Data Center, Container Data Center
Refrigerant:
R410A/R407C
Product Condition:
New
Product Type:
In Row Air Cooling Units
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Power Supply:
380/400 VAC,230 VAC,220V , 50/60HZ
Warranty:
1 Year(12months)
Product Name:
Row Based Cooling Unit
Capacity:
20-40KW
Mounting:
Floor Standing
Application:
Modularized Data Center, High Heat Density Data Center, Container Data Center
Refrigerant:
R410A/R407C
Product Condition:
New
Product Type:
In Row Air Cooling Units
After-sales Service Provided:
Engineers Available To Service Machinery Overseas
Power Supply:
380/400 VAC,230 VAC,220V , 50/60HZ
Warranty:
1 Year(12months)
Product Name:
Row Based Cooling Unit
In Row Air Conditioners For Data Centers And Network Management Centers

In-Row Precision Air Conditioners For Data Centers And Network Management Centers

 

Product Introduction                                       

Inrow cooling precisely cools and conditions air in close proximity and is targeted cooling at the banks of server cabinets that fill the data center. They can be installed on the floor or suspended from overhead making them closer to the actual rack. This setup offers both capacity and efficiency gains. Neither cool air nor warm exhaust air has far to travel, allowing the units to dissipate high heat loads quicker and allows a more scalable approach to cooling your data center.

 

Application                                       

  • Single rack with power larger than 3kW
  • High heat density computer room
  • Modular DC
  • Container type DC
  • DC with low PUE
  • Hot spot reconstruction
In Row Air Conditioners For Data Centers And Network Management Centers 0

Air Supply Method                                         

In Row Air Conditioners For Data Centers And Network Management Centers 1 In Row Air Conditioners For Data Centers And Network Management Centers 2

 

Features                                      

In Row Air Conditioners For Data Centers And Network Management Centers 3

Energy Efficiency

Inverter compressor, EC fan and electronic expansion valve are standard configurations for DXA series

Air is directly drawn from the hot aisle, allowing the unit to take advantage of higher heat transfer efficiency due to higher Delta T.

Cold aisle/Hot ailse containment avoids mixing of cold and hot air

 

High Flexibility

Air-cooled or chilled water-cooled cooling scheme.

Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.

 

High Reliability & Serviceability

24*7 uninterruptible operation design.

Multiple units in data centers, the total cooling capacity will not lower too much until the failed unit can be repaired.

 

Optional Features

Electrical heater and humidifier

Condensate pump

Floor water leakage alarm

ATS

 

Intelligent Control System

Highest protection against downtime, equipment damage and excess wear and tear.

Touched screen interface offers the full visibility.

AIRSYS NetOne Monitoring & Control for multiple units teamwork. integrated the latest technology of AI, ML and IoT to provide the monitoring and reliability for a more efficient operation of the cooling system.

Technical Parameter                        

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC        
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

 

Certificates                                                   

In Row Air Conditioners For Data Centers And Network Management Centers 4

 