Product Details
Place of Origin: China
Brand Name: Coolent
Certification: ISO/CE
Model Number: XR023-040
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: to be Negotiated
Packaging Details: WOODEN
Delivery Time: 4W
Payment Terms: T/T
Supply Ability: 1000/Month
Capacity: |
20-40KW |
Mounting: |
Floor Standing |
Application: |
Modularized Data Center, High Heat Density Data Center, Container Data Center |
Refrigerant: |
R410A/R407C |
Product Condition: |
New |
Product Type: |
In Row Air Cooling Units |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Power Supply: |
380/400 VAC,230 VAC,220V , 50/60HZ |
Warranty: |
1 Year(12months) |
Product Name: |
Row Based Cooling Unit |
Capacity: |
20-40KW |
Mounting: |
Floor Standing |
Application: |
Modularized Data Center, High Heat Density Data Center, Container Data Center |
Refrigerant: |
R410A/R407C |
Product Condition: |
New |
Product Type: |
In Row Air Cooling Units |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Power Supply: |
380/400 VAC,230 VAC,220V , 50/60HZ |
Warranty: |
1 Year(12months) |
Product Name: |
Row Based Cooling Unit |
In-Row Precision Air Conditioners For Data Centers And Network Management Centers
Product Introduction Inrow cooling precisely cools and conditions air in close proximity and is targeted cooling at the banks of server cabinets that fill the data center. They can be installed on the floor or suspended from overhead making them closer to the actual rack. This setup offers both capacity and efficiency gains. Neither cool air nor warm exhaust air has far to travel, allowing the units to dissipate high heat loads quicker and allows a more scalable approach to cooling your data center.
Application
|
Air Supply Method
Features
Energy Efficiency Inverter compressor, EC fan and electronic expansion valve are standard configurations for DXA series Air is directly drawn from the hot aisle, allowing the unit to take advantage of higher heat transfer efficiency due to higher Delta T. Cold aisle/Hot ailse containment avoids mixing of cold and hot air
High Flexibility Air-cooled or chilled water-cooled cooling scheme. Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.
High Reliability & Serviceability 24*7 uninterruptible operation design. Multiple units in data centers, the total cooling capacity will not lower too much until the failed unit can be repaired.
Optional Features Electrical heater and humidifier Condensate pump Floor water leakage alarm ATS
Intelligent Control System Highest protection against downtime, equipment damage and excess wear and tear. Touched screen interface offers the full visibility. AIRSYS NetOne Monitoring & Control for multiple units teamwork. integrated the latest technology of AI, ML and IoT to provide the monitoring and reliability for a more efficient operation of the cooling system. |
Technical Parameter
Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
Air supply | Front/Side | Front/Side | Front | Front | Front |
Power supply | 380VAC/3Ph/50Hz | ||||
Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Compressor | |||||
Refrigerant | R410A | ||||
Quantity | 1 | ||||
Fan | |||||
Fan type | EC Centrifugal fan | ||||
Quantity | 4 | 5 | 2 | 3 | 3 |
Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
Heater | |||||
Heat type | PTC | ||||
Capacity-KW | 2 | 3 | 6 | 6 | 6 |
Humidification | |||||
Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |