Product Details
Place of Origin: China
Brand Name: Coolent
Certification: ISO/CE
Model Number: XR060A
Payment & Shipping Terms
Minimum Order Quantity: 1Unit
Price: USD2000-30000/Unit
Packaging Details: Packed in plywooden case, standard export package
Delivery Time: 20-35Working Days
Payment Terms: T/T, L/C
Supply Ability: 1000/Month
Capacity: |
50-60KW |
Product Mounting: |
Floor Standing |
Product Application: |
Modularized Data Center, High Heat Density Data Center, Container Data Center |
Refrigerant: |
R410A |
Type: |
In Row Air Cooling Units |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Power Supply: |
380/400 VAC,230 VAC,220V , 50/60HZ |
Name: |
Row Based Cooling Unit |
Capacity: |
50-60KW |
Product Mounting: |
Floor Standing |
Product Application: |
Modularized Data Center, High Heat Density Data Center, Container Data Center |
Refrigerant: |
R410A |
Type: |
In Row Air Cooling Units |
After-sales Service Provided: |
Engineers Available To Service Machinery Overseas |
Power Supply: |
380/400 VAC,230 VAC,220V , 50/60HZ |
Name: |
Row Based Cooling Unit |
In Row Air Cooling Units For Modularized Data Center 50-60kw
Product Introduction In row air conditioning are also known as cool row air conditioning. Placed between the server cabinet columns, the heat source directly cooling equipment, row row room precision air conditioner belongs to the mechanical room air conditioning. The heat dissipation of the server and communication equipment in the data center is increasing. Therefore, the cooling method of the forward air conditioner cannot meet the requirements of the equipment for temperature and humidity. In order to effectively cool the equipment and prevent local overheating, cool air must enter the equipment inside the tissue for heat removal.
Feature & Benefits
|
Scope of Application
In row air conditioners are specially designed for modern modular data centers, such as high-thermal density data centers, various modular data centers, data centers with low PUE requirements, local hot spots in the equipment room, high-thermal density areas in medium-large equipment rooms, and data centers with limited equipment room area. |
Air Supply Method
Structure & Componenets
7 inch touch screen, running status and alarm display, advanced man-machine interface, to achieve simple and fast operation, professional, energy saving, intelligent and other functions.
Efficient DESIGN OF hydrophilic fin and inner threaded pipe, advanced technology, corrosion resistance, long life, high efficiency, and compressor and other refrigeration system components complete matching.
The backward EC fan has the advantages of high efficiency, energy saving, low noise, and continuous air volume.
Electrode humidifier, using tap water, with automatic cleaning function, quickly produce pure steam, maintenance without stopping. |
Technical Parameter
Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
Air supply | Front/Side | Front/Side | Front | Front | Front |
Power supply | 380VAC/3Ph/50Hz | ||||
Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Compressor | |||||
Refrigerant | R410A | ||||
Quantity | 1 | ||||
Fan | |||||
Fan type | EC Centrifugal fan | ||||
Quantity | 4 | 5 | 2 | 3 | 3 |
Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
Heater | |||||
Heat type | PTC | ||||
Capacity-KW | 2 | 3 | 6 | 6 | 6 |
Humidification | |||||
Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |
Factory Details
Packing & Delivery
|
Cases
|